Assembly (Figure-1)
Remove the protective film from the external
panels. Any adhesive remaining must be removed
with a suitable solvent.
If you will use the appliance with cupboard or
oven, use reference pins to put the appliance on
cupboard/oven and set the balance of unit with
foot(4 pcs.) on flat floor.
If you will use the appliance on support leg
system, use reference pins to put the appliance on
leg system.
If you will use the appliance on working table, use
plastic foot at the bottom of appliance
In the case of cantilever installations, refer to the
corresponding instructions.
Joining appliances together in line (Fig. 2)
Place the appliances side by side and adjust to the
same height.
Join the appliances by use of the special fixing
holes on the side of the cooktop.
Connection to the gas supply
Before making the connection consult the gas
supplier.
Gas inlet can be made from under or behind
the appliance.
Install a fast closing stopcock in an easily
accessible position upline from the appliance.
Confirm the absence of leaks at the points of
connection.
Confirm that the appliance is suitable for the type
of gas with which it will be supplied. If not, read
the paragraph “Modification for other type of
gas”.
All pieces needed for montage will be supplied by
manufacturing company.
Gas flex and gas hose connections must be carried
out in accordance with TS EN 14800 standard.
MODIFICATION FOR OTHER TYPE OF
GAS
ATTENTION! The appliance must
only be turned into different gases by
authorized service personnel.
The appliance has been adjusted to operate with
20mbar NG(G20).
To adapt the appliance to another type of gas,
carry out all the operations set out below.
The injectors, the minimum screws of the gas taps
which control the cooktop burners and the
adhesive labels, are contained in a bag supplied
with the appliance.
1. Replacement of burner injectors (Figure-3)
Remove the grill and the oil pan under it.
Receive pieces 1 and 2
Remove"7" injector from the "8" injector
connecting piece
Select the new injector suitable for the gas to be
used referring to Table"T2", and fasten to the "8"
injector adapter.
2. Closed Casting models (Figure-3)
Remove the screws by removing the gas control
knob and remove the front panel.
Unscrew and remove the "7" injector from the "8"
injector connecting piece.
Select the new injector suitable for the gas to be
used referring to Table"T2", and fasten to the "8"
injector adapter.
Burner Air Adjustment
1. For open burner models
Kindle the main burner and adjust the gas control
knob to "max. flame "
After to loosen the screw that fits the air
adjustment plate, adjust the ideal combustion of
the burner flame by sliding back and forth
After the burner burned a few minutes, adjust
control knob to the "min. flames" position.
Meanwhile, the burner should be in a constant
burning.
If the burner flame goes out or it is too high, in
this case low settings must be entered with the
"VM" adjustment screws on gas tap.
2. For closed burner models
Remove the front panel of the device.
Kindle the main burner and adjust the gas control
knob to "max. flame "
Loosen the screw "M" and ensure ideal
combustion of the flame according to the type of
gas by sliding the "V" sleeve back and forth
according to the type of gas
After the burner burned a few minutes on max.,
adjust control knob to the "min. flames" position.
Meanwhile, the burner should be in a constant
burning.
If the burner flame goes out or it is too
high, in this case low settings must be entered
with the "VM" adjustment screws on gas tap.
(Figure -4)
3. In the ovens (Figure 6)
•Remove the bottom panel under the oven door.
• Turn on the burner and set the throttle control
knob to position “7..
• Move the air adjustment plate ideal H ileri back
and forth according to the type of gas to ensure an
ideal combustion of the gas flame.
4. Replacing the pilot injector
(Figure-5 for the oven)