GB
INSTALLATION INSTRUCTIONS
WARNINGS
Installation, modifications and maintenance of
the appliance must be carried out by authorised
personnel in compliance with current safety
standarts.
The manufacturer declines all responsibility for
failure to comply with these obligations.
The instructions contained in this manual give
important regarding security for installing and
maintaining the appliance. The manufacturer
recommends that this manual be carefully stored
in the work zone where it can be consulted by
technicians and workers.
Electric connection of the appliance must be
according to the instructions given on the
technical data table and electric scheme.
Disrespect of the instruction given by producer
with the appliance (Use, maintenance, electric
connectin, technical data table and data plate)
may compromise the appliance safety and will
result in immediate loss of the warranty. The
manufacturer declines all responsibility for injury
or damage to persons or things, due to disrespect
of the instructions.
INSTALLATION
Positioning
The appliance should be placed under an exhaust
hood to remove smoke and smell which may
occur during the cooking process.
Position the appliance at least 10 cm from
surrounding walls. This distance may be reduced
if the walls are flameproof or protected by
insulating material.
Assembly
The appliance should be placed on a flat surface
by balancing it due to its four adjustable feet.
Remove the protective nylon on the appliance. If
sticky particles left on the appliance, clean them
with a suitable solvent.
In the case of cantilever installations, refer to the
corresponding instructions.
Joining appliances together in line (Fig. 1)
Place the appliances side by side and level to the
same height.
Join the appliances by use of the special fixing
holes on the side of the fryer.
Electrical connections
The appliance is designed to operate at the
voltage indicated on the data plate.
Each appliance must be connected to the power
supply by a suitably dimensioned independent
line (the total power is indicated in the "Technical
data" table). A flexible rubber cable with
insulation specifications not lower than type H 07
RN-F must be used for connection to the
temiinals.
The length of conductors between the cable clamp
and terminals must be such that the live wires are
pulled taut before the ground wire (yellow-green)
if the cable is worked loose from the clamp.
Multi-pole main isolating switches of suitable
current ratin. (with minimum contact-breaking
distance of 3 mm) must be installed, as well as
automatic residual current switches of suitable
high sensitivity.
There should be a automate fuse between the
appliance and the network.
Voltage changes should not exceed %10V.
Ground connections and equipotential bonding
The appliance must be connected to the ground
circuit using the terminals marked by the symbol
located next to the connection terminals.
The metal structure of all the electrical appliances
must also be connected to the ground circuit using
the terminals marked by the symbol
located next to the earth terminals (equipotential
bonding system).
Water connection
The water inlet pressure must be set between 1,5
÷ 2,5 bar.
The unit be supplied with drinkable water.
The water inlet hose be connected with the water
main by means of stop cock to be shut off when
the unit is not operating or during servicing.
A mechanic filter should be placed between the
appliance and the taps (Cold-hot). That filter will
hold the dirt and the metal particles which cause
oxidation at the interior surface of the appliance.
Before the connnection of the last pipe to the
appliance, the dirt should be removed by
discharging some water.
Water drain
Open the global valve in the bottom of the tank
and discharge the water in the tank.
Important : The tank drain must be connected to
the drainage system using a pipe resistant to high
temperatures (1000C).
SETTING UP
Testing the electrical system