Dell PowerEdge C6300 El kitabı

Tip
El kitabı
Dell PowerEdge C6320
Getting Started
With Your System
Začínáme se systémem
Mise en route du système
Erste Schritte mit dem System
Τα πρώτα βήματα στο σύστημά σας
Rozpoczynanie pracy z systemem
Начало работы с системой
Početak rada sa sistemom
Procedimientos iniciales con el sistema
Sisteminizi Kullanmaya Başlarken
תליחת הדובעה םע תכרעמה
Scan to see how-to videos, documentation, and
troubleshooting information.
Naleznete zde videa s postupy, dokumentaci
a informace o řešení potíží.
Scannez pour voir des didacticiels vidéo, obtenir de la
documentation et des informations de dépannage.
Scannen, um Videos zu Hilfe und Anleitungen, Dokumentationen
und Informationen zur Fehlerbehebung zu sehen.
Αναζητήστε βίντεο για τον τρόπο χρήσης του συστήματος,
τεκμηρίωση και πληροφορίες για την αντιμετώπιση προβλημάτων.
Zeskanuj, aby wyświetlić instruktażowe filmy wideo
i informacje o rozwiązywaniu problemów.
Сканируйте, чтобы просмотреть обучающее видео,
документацию и информацию по устранению неисправностей.
Skenirajte da biste videli video uputstva, dokumentaciju
i informacije o rešavanju problema.
Escaneo para ver vídeos sobre procedimientos, documentación
e información para la solución de problemas.
Tarama nasıl yapılır videoları, belgeler ve
sorun giderme bilgilerini görmek için.
קורס ידכ תוארל עדימ יבגל ינוטרס הכרדה ,דועית ןורתפו תויעב.
Dell PowerEdge
C6320
Getting Started
With Your System
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better
use of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or
loss of data if instructions are not followed.
WARNING: A WARNING indicates a potential for property damage,
personal injury, or death.
______________
Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international
copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the
United States and/or other jurisdictions. All other marks and names mentioned herein may be
trademarks of their respective companies.
Regulatory Model: B08S Regulatory Type: B08S003
2015 - 03 P/N CFK9F Rev. A00
6 | Getting Started With Your System
CAUTION: Restricted Access Location
This server is intended for installation only in restricted access locations as defined in
Cl. 1.2.7.3 of IEC 60950-1: 2001 where both these conditions apply:
Access can only be gained by service persons or by users who have been
instructed about the reasons for the restrictions applied to the location and
about any precautions that shall be taken.
Access is through the use of a tool or lock and key, or other means of security,
and is controlled by the authority responsible for the location.
Installation and Configuration
WARNING: Before performing the following procedure, review and follow
the safety instructions that came with the system.
Installing the Tool-Less Rail Solution
WARNING: Whenever you need to lift the system, get others to assist
you. To avoid injury, do not attempt to lift the system by yourself.
WARNING: The system is not fixed to the rack or mounted on the
rails. To avoid personal injury or damage to the system, you must
adequately support the system during installation and removal.
WARNING: To avoid a potential electrical shock hazard, a third wire
safety grounding conductor is necessary for the rack installation.
The rack equipment must provide sufficient airflow to the system to
maintain proper cooling.
CAUTION: When installing rails in a square-hole rack it is important
to ensure that the square peg slides through the square holes.
Getting Started With Your System | 7
1 Push the latch release buttons on the midpoints of the end piece to open the
rail latches. See Figure 1.
2 Align the end pieces of the rails on the vertical rack flanges to seat the pegs
in the bottom hole of the first U and the top hole of the second U.
NOTE: The rails can be used in both square-hole (item 1 in the
following figure) and round-hole racks (item 2 in the following figure).
Figure 1. Pushing the Latch Release Buttons
NOTE: To remove the rails, push the latch release button on the
midpoints of the end piece and unseat each rail.
8 | Getting Started With Your System
3 Engage the end of the rails and release the latch release button to have the
latches locked in place. See Figure 2.
Figure 2. Releasing the Latch Release Buttons
4 On each vertical rack flange on the back, put two screw bases into the two
square holes right above the rail. See Figure 3.
5 Install the chassis stabilizer shipping brackets (optional) on the back rack
flanges.
Getting Started With Your System | 9
6 Install and tighten the screws.
NOTE: To transport systems already installed in the rack, ensure that
the two chassis stabilizer shipping brackets (optional) are in place.
Figure 3. Installing the Chassis Stabilizer Shipping Brackets
10 | Getting Started With Your System
7 Slide the system into the rack. See Figure 4.
8 Tighten the thumbscrews to secure the ears of the system to the front of the
rack flanges.
Figure 4. Installing the Chassis onto the Rack.
Getting Started With Your System | 11
Optional—Connecting the Keyboard, Mouse, and Monitor
Figure 5. Optional—Connecting the Keyboard, Mouse and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable to plug
into each connector. Be sure to tighten the screws (if any) on the monitor’s cable
connector.
NOTE: Note that the system supports only one USB port and a micro USB
port. If you require more than one USB outlet at a time, use USB Hub or
Adapter Cable.
12 | Getting Started With Your System
Connecting the Power Cable(s)
Figure 6. Connecting the Power Cable
Connect the system’s power cable(s) to the system and, if a monitor is used, connect
the monitor’s power cable to the monitor. Plug the other end of the power cables into
a grounded electrical outlet or a separate power source such as an uninterrupted power
supply or a power distribution unit.
NOTE: The system supports both AC and HVDC power inputs. Your system
can support up to two 1400 W power supply units (200-240 VAC nominal
input voltage) or up to two 1600 W power supply units (200-240 VAC nominal
input voltage). 1400 W power supply unit is supported only for China.
Getting Started With Your System | 13
Turning on the System
Figure 7. Pressing the Power Button on the Front of the System
Figure 8. Pressing the Power Button on the Back of the System
Press the power button(s) either on the front or back of the system. The power indicators
should light green.
14 | Getting Started With Your System
Complete the Operating System Setup
To install an operating system for the first time, see the installation and configuration
documentation for your operating system. Be sure the operating system is installed
before installing hardware or software not purchased with the system.
NOTE: See dell.com/ossupport for the latest information on supported operating
systems.
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with
your system. Warranty information may be included within this document
or as a separate document.
The Hardware Owner’s Manual provides information about system features and
describes how to troubleshoot the system and install or replace system components.
This document is available at dell.com/support/home.
Dell systems management application documentation provides information about
installing and using the systems management software. This document is available
online at dell.com/support/home.
For an immediate access to your system information:
1. Go to dell.com/support.
2. Enter your system service tag in the Enter your Service Tag field.
3. Click Submit.
The support page that lists the system manuals is displayed.
For more information about your system:
1. Go to dell.com/support.
2. Select your country from the drop-down menu on the top left corner of
the page.
a. Select your product category.
b. Select your product segment.
c. Select your product.
The support page that lists the various support categories is displayed.
NOTE: Always check for updates on dell.com/support/home and read the
updates first because they often supersede information in other documents.
Getting Started With Your System | 15
NOM Information (Mexico Only)
The following information is provided on the device described in this document in
compliance with the requirements of the official Mexican standards (NOM):
Importer Dell Inc. de México, S.A. de C.V.
Paseo de la Reforma 2620-11° Piso
Col. Lomas Atlas
11950 México, D.F.
Model number B08S
Supply voltage 200-240 V AC with 1400 W (for China
only) or 1600 W Power Supply Unit
Frequency 50/60 Hz
Current consumption 9 Amps with 1400 W Power Supply Unit
10 Amps with 1600 W Power Supply Unit
Technical Specifications
Processor Two Intel Xeon E5-2600 v3
Memory
Architecture 1600 MT/s, 1866 MT/s, or
2133 MT/s DDR4 Registered
DIMMs
Support for advanced ECC or
memory optimized operation
Memory module sockets Twelve 288-pin
16 | Getting Started With Your System
Memory module capacities (RDIMMs) 8 GB and 16 GB dual-rank
Minimum RAM
Maximum RAM
16 GB
Up to 256 GB
Power
NOTE: The system does not support a mixed installation of 1400 W and
1600 W power supply units.
NOTE: The 1400 W and 1600 W power supply units are hot swappable,
and supports hot swap in any condition if the system has the power
throttling feature.
AC power supply (per power supply)
Wattage 1400 W (for China only)
Voltage 200-240 VAC, 50/60 Hz, maximum
input current: 9 Amps
Heat dissipation 6024.376 BTU/hr maximum
Maximum inrush current
Initial In-rush Current cannot exceed
55 Amps (peak). Secondary In-rush
Current cannot exceed 25 Amps
(peak).
Wattage 1600 W
Voltage
200-240 VAC, 50/60 Hz, maximum
input current: 10 Amps
Getting Started With Your System | 17
Heat dissipation 6033.979 BTU/hr maximum
Maximum inrush current
Initial In-rush current and secondary
In-rush current cannot exceed
50 Amps (peak).
HVDC power supply (per power supply)
Wattage 1400 W (for China only)
Voltage 240 VDC, 50/60 Hz, maximum input
current: 9 Amps
Heat dissipation 5440.614 BTU/hr maximum
Maximum inrush current
Initial In-rush Current cannot exceed
55 Amps (peak). Secondary In-rush
Current cannot exceed 25 Amps
(peak).
Battery (per system board)
System battery CR 2032 3.0-V lithium ion coin cell
Physical
Height 8.68 cm (3.42 in)
Width 44.8 cm (17.6 in)
Depth 79.0 cm (31.1 in)
Weight (maximum configuration) 41 kg (90.38 lb)
(with 12*3.5” HDD)
39 kg (86.00 lb)
(with 24*2.5” HDD)
18 | Getting Started With Your System
Weight (empty) 15.7 kg (34.61 lb)
(with 2.5” HDD bay)
15.1 kg (33.29 lb)
(with 3.5” HDD bay)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating 10° to 35°C (50° to 95°F) with
a maximum temperature gradation
of 10°C per hour
NOTE: For altitudes above 2950 feet,
the maximum operating temperature
is derated 1°F/550 ft.
CAUTION: The maximum number of
memory modules and hard drives
supported on 1U node configuration,
with 135W and 145W processors,
depends on the power supply installed.
Storage –40° to 65°C (–40° to 149°F) with
a maximum temperature gradation of
20°C per hour
Relative humidity
Operating 20% to 80% (noncondensing) with
a maximum humidity gradation of
10% per hour
Storage 5% to 95% (noncondensing)
Maximum vibration
Operating 0.26 Grms at 5–350 Hz
Storage 1.88 Grms at 10–500 Hz for 15 min
Getting Started With Your System | 19
Maximum shock
Operating One shock pulse in the positive
z axis (one pulse on each side of the
system) of 31 G for 2.6 ms in the
operational orientation
Storage Six consecutively executed shock
pulses in the positive and negative x,
y, and z axes (one pulse on each side
of the system) of 71 G for up to 2 ms;
Six consecutively executed shock
pulses in the positive and negative x,
y, and z axes (one pulse on each side
of the system) of 27 G faired square
wave pulse with velocity change
at 235 inches/second
(597 centimeters/second)
Altitude
Operating -15.2 to 3,048 m
(-50 to 10,000 ft.)
Storage -15.2 to 10,668 m
(-50 to 35,000 ft.)
Airborne Contaminant Level
Class G1 as defined by
ISA-S71.04-1985
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200

Dell PowerEdge C6300 El kitabı

Tip
El kitabı