5019 100 75185/A
AKR 926-927
1
4
2
2
3
1.
Control panel
2.
Grease filters
3.
Lighting unit
4.
Telescopic flue
Cleaning the grease filter
Wash the grease filter once a month, or whenever
the grease filter saturation indicator flashes
(Extraction speed indicator
2
).
1.
Unplug the appliance or disconnect the mains
power supply.
2.
Remove the grease filters: push the handles
towards the lighting unit, then downwards
(a,b - Fig. 1)
.
3.
After washing the metal grease filter, remount in
reverse order ensuring that the entire extraction
surface is covered.
Replacing bulbs
1.
Unplug the appliance or disconnect the mains
power supply.
2.
Unscrew the lighting unit
(c - Fig. 2)
.
3.
Remove the burnt-out bulb
(d - Fig. 2)
.
Replace using 20W max bulbs only.
4.
Screw the lighting unit back in place.
Carbon filter Fitting and Maintenance
Fitting the carbon filter:
1.
Unplug the appliance or disconnect the mains
power supply.
2.
Remove the grease filters
(a,b - Fig. 1)
.
3.
Remove the screw and then the filter holder
(e - Fig. 3)
.
4.
Fit the carbon filter
(f - Fig. 3)
in the filter holder
(g - Fig. 3)
.
5.
Refit the filter holder and secure it to the hood
with the screws
(g - Fig. 3)
.
6.
Refit the grease filters.
Carbon filter maintenance:
Unlike traditional carbon filters, this carbon filter can
be washed and reactivated.
With normal hood use, the filter should be cleaned
once a month or whenever the carbon filter
saturation indicator flashes (extraction speed
indicator
3
). The filter is best washed in a
dishwasher at the highest temperature possible,
using a normal dishwasher detergent. To avoid
particles of food or dirt settling on the filter during
washing and giving rise to unpleasant smells, it is
advisable to wash the filter on its own. After
washing, dry the filter in the oven at 100° C for
10 minutes to reactivate it.
The filter will retain its odour-absorbing capacity for
three years, after which it will have to be replaced.
Reset filter indicator:
Press the extraction OFF
button until LED
2
and/or LED
3
stop flashing.
THE CONTROL PANEL
1.
Extraction OFF button.
2.
Extraction ON speed increase button
- 1
Ö
3
Ö
1 ......
3.
Extraction speed indicator
1
.
4.
Extraction speed indicator
2
and grease filter
saturation indicator (when flashing).
5.
Extraction speed
3
and carbon filter saturation
indicator (when flashing):
this function is
normally deactivated. In order to activate it
press buttons 2 and 7 at the same time until the
carbon filter saturation indicator starts flashing.
To deactivate the function repeat the operation
.
6. Intensive
extraction speed indicator.
7.
Timed intensive speed button: the hood
operates at this speed for 5 minutes and then
returns to the previous settings.
This function can be cancelled by pressing
button
1
or
2
.
8.
Light OFF button.
9.
Light ON button.
1
2
3
45
6
7
89
Fig. 2
Fig. 1
Fig. 3
Fig. 4
PRODUCT SHEET
F NL E PGBD GRI
75185A.fm5 Page 6 Monday, November 6, 2000 3:57 PM