LG AMNW24GECA0 El kitabı

Kategori
Mobil klimalar
Tip
El kitabı

Bu kılavuz için de uygundur

OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
www.lg.com
TYPE : WALL MOUNTED
MODELS : AMNW07GEWA0, AMNW09GEBA0, AMNW12GEBA0
AMNW18GECA0, AMNW24GECA0
P/NO : MFL67737103
ENGLISH
TÜRKÇE
2
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con-
ditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block
the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
SAFETY PRECAUTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation MUST conform with local building codes or, in the absence of local codes, with
the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal-
function, property damage, personal injury and/or death.
Installation
• Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Fail-
ure to do so may result in electric shock or product failure.
• Contact an authorized service center when you install or relocate the air conditioner. Failure to
do so may result in serious injury or product failure.
• Always use a power plug and socket with a ground terminal.Failure to do so may result in
electric shock or product failure
• Install the panel and the cover of the control box safely. Failure to do so may result in explo-
sion or fire.
• Install a dedicated electric outlet and circuit breaker before you use the air conditioner. Failure
to do so may result in electric shock or product failure.
• Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Fail-
ure to do so may result in electric shock or product failure.
• Do not modify or extend the power cable. If the power cable or cord has scratches or skin
peeled off or deteriorated then it must be replaced. It may result in fire or electric shock.
• Be cautious when you unpack or install the air conditioner. Failure to do so may result in seri-
ous injury or product failure.
• Contact an authorized service center when you install or relocate the air conditioner. Failure to
do so may result in serious injury or product failure.
• Do not install the air conditioner on an unstable surface or where there may be a danger of it
falling. It may result in death, serious injury, or product failure.
!
!
!
3
ENGLISH
4
SAFETY PRECAUTIONS
ENGLISH
Operation
• Do not let the air conditioner run for a long time when the humidity is very high or when a door or
window has been left open. Failure to do so may result in product failure.
• Make sure that the power cord is not pulled or damaged while the air conditioner is operating. Fail-
ure to do so may result in fire, electric shock, or product failure.
• Do not place any objects on the power cord. It may result in electric shock or product failure.
• Do not turn on or off the air conditioner by plugging in or unplugging the power plug. It may result in
fire or electric shock.
• Do not touch, operate or repair the air conditioner with wet hands. It may result in electric shock or
product failure.
• Do not place a heater or other heating appliances near the power cable. It may result in fire, electric
shock, or product failure.
• Do not allow water to run into the air conditioner. It may result in explosion or fire.
• Do not leave flammable substances such as gasoline, benzene and thinner near the air conditioner.
It may result in explosion or fire.
• Do not use the air conditioner for an extended period of time in a small place without ventilation.
Ventilate the place regularly. Failure to do so may result in explosion or fire.
• When there is a gas leak, ventilate sufficiently before using the air conditioner again. Failure to do so
may result in explosion or fire.
• Unplug the power plug if there is a noise, smell or smoke coming from the air conditioner. Failure to
do so may result in explosion or fire.
• Stop operating and close the window in strom or hurricane.If possible remove the product from the
window before hurricane arrives
• Do not touch the electrostatic filter after opening the front grille. Failure to do so may result in elec-
tric shock or product failure.
• Contact an authorized service center when the air conditioner is submerged into water due to flood-
ing. Failure to do so may result in explosion or fire.
• Be cautious water could not enter the product
• Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater
are used simultaneously. Failure to do so may result in fire, serious injury, or product failure.
• Turn the main power off and unplug the power plug when you clean or repair the air conditioner.
Failure to do so may result in death, serious injury, or product failure.
• Unplug the power plug when the air conditioner is not used for an extended period of time. Failure
to do so may result in product failure.
• Do not place any objects on the air conditioner. It may result in product failure.
• For inner cleaning, contact an Authorized Service Center or a dealer.
Do not use harsh detergent that causes corrosion or damage on the unit.
Harsh detergent may also cause failure of product, fire, or electronic shock.
SAFETY PRECAUTIONS
CAUTION
Installation
• Make sure to check if there is a refrigerant leak after you install or repair the air conditioner. Failure
to do so may result in product failure.
• Install the drain hose properly for smooth drainage of condensed water. Failure to do so may result
in product failure.
• Keep level even when installing the product.
• Install the air conditioner where the noise from the outdoor unit or the exhaust gas will not incon-
venience the neighbors. Failure to do so may result in conflict between neighbors.
• When transporting the equipment, there should be at least 2 or more people, or a forklift. It may re-
sult in serious injury.
• Do not install the air conditioner where it will be exposed to sea wind (salt spray) directly. It may re-
sult in product failure.
Operation
• Do not expose people, animals or plants to the cold or hot wind from the air conditioner. It may re-
sult in serious injury.
• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a con-
sumer air conditioner, not a precision refrigeration system. It may result in death, fire or electric
shock.
• Do not block the inlet or outlet of air flow. It may result in explosion or product failure.
• Do not use strong cleaning agents or solvents when you clean the air conditioner, or spray water.
Use a smooth cloth. It may result in serious injury or product failure.
• Never touch the metal parts of the air conditioner when you remove the air filter. It may result in se-
rious injury or product failure.
• Do not place any objects on the air conditioner. It may result in product failure.
• Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if
necessary.
• Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operat-
ing. It may result in electric shock.
• Do not drink the water drained from the air conditioner. It may result in serious health complications.
• Use a sturdy stool or ladder when you clean, maintain or repair the air conditioner at a height. Failure
to do so may result in serious injury or product failure.
• Do not mix the batteries for the remote control with other types of batteries or mix new batteries
with used batteries. Failure to do so may result in product failure.
• Do not recharge or disassemble the batteries. Failure to do so may result in explosion, fire or serious
injury.
• Stop using the remote control if there is a battery fluid leak. If your cloth or skin is exposed to the
battery fluid from a leak, wash it off with clean water. Failure to do so may result in serious injury.
• If you swallow the battery fluid from a leak, wash out the inside of your mouth thoroughly and then
consult a doctor. Failure to do so may result in serious health complications.
!
5
ENGLISH
TABLE OF CONTENTS
2
TIPS FOR SAVING ENERGY
3 IMPORTANT SAFETY
INSTRUCTIONS
7 BEFORE USE
7 Components
8 Using the remote control
9 - Inserting batteries
9 - Installing the remote control holder
10 BASIC FUNCTIONS
10 Cooling your room
10 Heating your room
10 Removing humidity
11 Airing your room
11 Adjusting the fan speed
11 Adjusting the air flow direction
11 Setting the timer
11 - Setting the current time
12 - Turning on the air conditioner
automatically at a set time
12 - Turning off the air conditioner
automatically at a set time
12 - Canceling the timer setting
12 Setting sleep mode
13 ADVANCED FUNCTIONS
13 Changing room temperature quickly
13 Indoor air purification
13 - Auto Clean operation
14 Plasma Purification operation
14 Auto operation
15 Auto Changeover operation
15 Energy saving cooling mode
15 Display screen brightness
16 Operating the air conditioner without the
remote control
16 Restarting the air conditioner
automatically
17 MAINTENANCE
18 Cleaning the air filter
18 Cleaning the anti-allergy filter and triple
filter
18 Cleaning the plasma filter
19 TROUBLESHOOTING
19 Self-diagnosis function
19 Before requesting service
TABLE OF CONTENTS
6
ENGLISH
Air inlet vents
Air outlet vents
Base plate
Coolant piping
Connection
wire
Drain hose
BEFORE USE
Components
Outdoor unit
Operation
lamp
Signal Receiver
ON/OFF button
Air inlet
Air filter
Front grille
Vertical louver
Anti-allergy filter
Air outlet
Horizontal
vane
Triple filter
NOTE
!
The number of operation lamps and their locations may vary, depending on the model of the
air conditioner.
7
BEFORE USE
ENGLISH
Indoor unit
* The feature can be changed according a type of model.
* The feature can be changed according a type of model.
Using the remote control
You can operate the air conditioner more conveniently with the remote control. You will find the
buttons for the additional functions under the cover of the remote control.
Wireless remote control
Display
screen
Control
panel
* Some functions may not be supported, depending on the
model.
Control
panel
Display
screen
Description
/
E
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling
or heating.
l
=
Sleep mode auto button*: Sets the
sleep mode auto operation.
e
y
Temperature adjustment buttons: Ad-
justs the room temperature when cool-
ing and heating.
d
- On/Off button: Turns the power on/off.
g
7
v
Indoor fan speed button: Adjusts the
fan speed.
f
AC
DB
Operation mode selection button*: Se-
lects the operation mode.
Cooling operation (A) / Auto operation
or auto changeover (C) / Dehumidify-
ing operation (D) / Heating operation
(B)
h
N
Jet cooling/heating button*: Warms up
or cools down the indoor temperature
within a short period of time.
ij
HI
Air flow direction button*: Adjusts the air
flow direction vertically or horizontally.
k
S
Temperature display button: Displays the
room temperature. Also changes unit
from °C to °F if pressed for 5 seconds.
mn
z
Timer button: Sets the current time and
the start / end time.
c
b
\
JG
Navigation and functions button*:
Adjusts the time and sets the special
functions.
J: Auto clean / G: Operates energy
saving cooling / LIGHT : Adjusts the
brightness of the indoor unit display
p
-
Set/clear button: Sets or cancels func-
tions.
r
-
Reset button: Resets the air condi-
tioner settings.
BEFORE USE
8
ENGLISH
Inserting batteries
Insert batteries before using the remote
control. The battery type used is AAA (1.5 V).
1 Remove the battery cover.
2 Insert the new batteries and make sure
that the + and - terminals of the batteries
are installed correctly.
3 Reattach the battery cover.
Installing the remote control holder
Install the holder where there is no direct sun-
light to protect the remote control.
1 Choose a safe and easily-accessible place.
2 Fix the holder by fastening the 2 screws
firmly with a screwdriver.
3 Slide the remote control into the holder.
Point the remote control towards the signal
receiver at the bottom of the air conditioner to
operate it.
NOTE
!
If the display screen of the remote control
starts to fade, replace the batteries.
NOTE
!
• The remote control may operate other
electronic devices if pointed towards
them. Make sure to point the remote
control towards the signal receiver of
the air conditioner.
• For proper operation, use a soft cloth to
clean the signal transmitter and receiver.
Operating method
9
BEFORE USE
ENGLISH
BASIC FUNCTIONS
Cooling your room
(Cooling operation)
1 Press d to turn on the power.
2 Press f repeatedly to select the cooling
operation.
- A is displayed on the display screen.
3 Press u or v to set the desired tempera-
ture.
- The temperature range is 18°C - 30°C.
Heating your room
(Heating operation)
1 Press d to turn on the power.
2 Press f repeatedly to select the heating
operation.
- B is displayed on the display screen.
3 Press u or v to set the desired tempera-
ture.
- The temperature range is 16°C - 30°C
Removing humidity
(Dehumidifying operation)
This mode removes excess moisture from an
environment with high humidity or in the rainy
season, in order to prevent mold from setting
in. This mode adjusts the room temperature
and the fan speed automatically to maintain
the optimal level of humidity.
1 Press d to turn on the power.
2 Press f repeatedly to select the dehu-
midifying operation.
-
D is displayed on the display screen.
NOTE
!
• In this mode you cannot adjust the room
temperature, as it is adjusted automati-
cally. Also, the room temperature is not
displayed on the display screen.
BASIC FUNCTIONS
10
ENGLISH
NOTE
!
Cooling-only models do not support this
function.
Airing your room
(Air Circulation operation)
This mode only circulates the indoor air
without changing the room temperature. The
cooling lamp lights up in air circulation mode.
1 Press d to turn on the power.
2 Press / to select the air circulation oper-
ation.
- E is displayed on the display screen.
3 Press g to adjust the fan speed.
Adjusting the fan speed
1 Press g repeatedly to adjust the fan
speed.
- Select
5
if you want natural air.
The fan speed adjusts automatically.
Adjusting the air flow direc-
tion
1 To adjust the direction of the air flow verti-
cally, press i repeatedly and select the
desired direction.
- Select H to adjust the direction of the air
flow automatically.
2 To adjust the direction of the air flow hori-
zontally, press j repeatedly and select
the desired direction.
- Select I to adjust the direction of the
air flow automatically.
Setting the timer
You can use the timer function to save energy
and to use the air conditioner more efficiently.
Setting the current time
1 Press p and hold it for longer than 3 sec-
onds.
- The AM/PM icon flickers at the bottom of
the display screen.
NOTE
!
• Adjusting the air flow direction horizon-
tally may not be supported, depending
on the model.
• Adjusting the air deflector arbitrarily may
cause product failure.
• If you restart the air conditioner, it starts
to operate with the previously set direc-
tion of air flow, so the air deflector may
not match the icon displayed on the re-
mote control. When this occurs, press
i or j to adjust the direction of the
air flow again.
11
BASIC FUNCTIONS
ENGLISH
2 Press
o
or
q
to select the minutes.
3 Press pto finish.
Turning on the air conditioner auto-
matically at a set time
1 Press m.
- The icon below flickers at the bottom of
the display screen.
2 Press
o
or
q
to select the minutes.
3 Press pto finish.
Turning off the air conditioner auto-
matically at a set time
1 Press n.
- The icon below flickers at the bottom of
the display screen.
2 Press
o
or
q
to select the minutes.
3 Press pto finish.
Canceling the timer setting
1 Press m.
2 Press m or n to select the timer setting
to cancel.
3 Press p.
- To cancel all timer settings, press
p.
Setting sleep mode
Use the sleep mode to turn off the air condi-
tioner automatically when you go to sleep.
1 Press dto turn on the power.
2 Press l
3 Press
o
or
q
to select the hour
(up to 7 hours).
4 Press pto finish.
-
T is displayed on the display screen in
sleep mode.
NOTE
!
In the Cooling and Dehumidifying modes,
the temperature increases by 1°C after 30
minutes and by a further 1°C after another
30 minutes for a more comfortable sleep.
The temperature increases with up to 2°C
from the preset temperature.
BASIC FUNCTIONS
12
ENGLISH
ADVANCED FUNCTIONS
The air conditioner offers some additional ad-
vanced functions.
Changing room temperature
quickly
(Jet Cool/Heat operation)
This mode allows you to cool indoor air quickly
in summer or warm it quickly in winter.
1 Press dto turn on the power.
2 Press h.
- In jet cooling mode, strong air blows out
at a temperature of 18°C for 30 minutes.
- In jet heating mode, strong air blows out
at a temperature of 30°C for 30 minutes.
Indoor air purification
Auto Clean operation
In the cooling and dehumidifying operations,
moisture is generated inside the indoor unit.
Use the auto cleaning function to remove
such moisture.
1 Press dto turn on the power.
2 Press c.
-
J is displayed on the display screen.
- If you turn off the power, the fan oper-
ates for 30 minutes and cleans the inside
of the indoor unit.
NOTE
!
• In Air Circulation, Auto, or Auto
Changeover mode, this function cannot
be used.
• This function may not be supported, de-
pending on the model.
13
ADVANCED FUNCTIONS
ENGLISH
NOTE
!
Some buttons cannot be used while the
auto cleaning function is in operation.
Plasma Purification operation
The plasma filter developed by LG removes
microscopic contaminants from the intake air
completely to supply clean and fresh air.
1 Press d to turn on the power.
2 Press a.
-
F is displayed on the display screen.
Auto operation
(Artificial intelligence)
You can set desired temperature and indoor
fan speed. Setting Temp. Range : 18~30°C
1 Press d to turn on the power.
2 Press f repeatedly to select auto opera-
tion.
NOTE
!
• You can use this function by pressing
a without turning the air conditioner
on.
• Both the plasma lamp and the cooling
lamp light up while plasma purification is
in operation.
• This function may not be supported, de-
pending on the model.
ADVANCED FUNCTIONS
14
ENGLISH
NOTE
!
• In this mode, you can set the air deflec-
tor to rotate automatically.
• This function may not be supported, de-
pending on the model.
Energy saving cooling mode
This mode minimizes power consumption dur-
ing cooling and increases the set temperature
to the optimal level for a more comfortable en-
vironment.
1 Press dto turn the power on.
2 Press frepeatedly to select the cooling
operation.
3 Press b.
-
G is displayed on the display screen.
Display screen brightness
You can adjust the brightness of the indoor
unit display screen.
1 Press \repeatedly to set the brightness
to the desired level.
Operating the air conditioner
without the remote control
You can use the On/Off button of the indoor
unit to operate the air conditioner when the
remote control is unavailable. However, the
fan speed is set to high.
1 Open the front cover.
- Lift up both sides of the cover slightly.
2 Press the On/Off button.
- For cooling and heating models, the oper-
ation mode changes, depending on the
room temperature.
- For cooling-only models, the temperature
is set to 22°C (71.6°F).
15
ADVANCED FUNCTIONS
ENGLISH
NOTE
!
This function may not be supported,
depending on the model.
NOTE
!
This function may not be supported,
depending on the model.
* The feature can be changed according a
type of model.
* The feature can be changed according a
type of model.
ON/OFF
button
Room temp. Set temp.
Operation
mode
Below 21°C 24°C
Heating
operation
Above 21°C
and below
24°C
23°C
Dehumidify-
ing operation
Above 24°C 22°C
Cooling
operation
Restarting the air conditioner
automatically
When the air conditioner is turned on again
after a power failure, this function restores the
previous settings. This function is a factory de-
fault setting.
1 Open the front cover.
- Lift up both sides of the cover slightly.
2 Press the On/Off button and hold it for 6
seconds.
- The unit will beep twice and the lamp will
blink 6 times.
- To re-enable the function, press the On/
Off button and hold it for 6 seconds. The
unit will beep twice and the blue lamp will
blink 4 times.
ON/OFF
button
Disabling auto restart
NOTE
!
If you press and hold the On/Off button
for 3 – 5 seconds instead of 6 seconds,
the unit will switch to the test operation.
In the test operation, the unit blows out
strong air for cooling for 18 minutes and
then returns to the factory default set-
tings.
ADVANCED FUNCTIONS
16
ENGLISH
* The feature can be changed according a
type of model.
* The feature can be changed according a
type of model.
MAINTENANCE
17
ENGLISH
MAINTENANCE
Clean the product regularly to maintain optimal performance and to prevent possible breakdown.
* This may not be provided, depending on the model.
Item Cleaning interval Cleaning method
Air filter 2 weeks See “Cleaning air filter.”
Anti-allergy filter / Triple filter 3 months
See “Cleaning anti-allergy filter and triple Filter.”
Plasma filter* 3 months See “Cleaning the plasma filter.”
Indoor unit surface Regularly
Use a soft, dry cloth. Do not use bleach or
abrasives.
Outdoor unit Regularly
Use steam to clean the heat exchanger coils
and the panel vents (consult with technician).
Plasma filter/
Anti-Allergy Filter
Triple FilterAir filter
CAUTION
• Turn off the power and unplug the power cord before you perform any maintenance; other-
wise it may cause electric shock.
• Never use water that is hotter than 40°C when you clean the filters. It may cause deforma-
tion or discoloration.
• Never use volatile substances when you clean the filters. They may damage the surface of
the product.
!
NOTE
!
• The location and shape of the filters may differ, depending on the model.
• Make sure to clean the heat exchanger coils of the outdoor unit regularly, as dirt collected
in the coils may decrease the operational efficiency or increase energy costs.
* The feature can be changed according a type of model.
18
MAINTENANCE
ENGLISH
Cleaning the air filter
Clean the air filter once every 2 weeks or
more if necessary.
1 Turn off the power and unplug the power
cord.
2 Open the front grille.
- Lift up both sides of the cover slightly.
3 Hold the knob of the air filter, lift it up
slightly and remove it from the unit.
4 Clean the filter with a vacuum cleaner or
with warm water.
- If dirt is difficult to remove, wash the filter
in lukewarm water with detergent.
5 Dry the filter in the shade.
Cleaning the anti-allergy filter
and triple filter
1 Turn off the power and unplug the power
cord.
2 Open the front grille and remove the air fil-
ter (see “Cleaning air filter”).
3 Pull out the anti-allergy filter and the triple
filter.
4 Dry the filter in direct sunlight for 2 hours.
Cleaning the plasma filter
1 Turn off the power and unplug the power
cord.
2 Open the front grille and remove the air fil-
ter (see “Cleaning air filter”).
3 Remove the plasma filter in 10 seconds.
4 Use a vacuum cleaner to remove any dirt.
- If dirt is difficult to remove, wash the filter
with lukewarm water.
5 Dry the filter in the shade.
NOTE
!
• The location and shape of the filters may
differ, depending on the model.
• The feature can be changed according a
type of model.
NOTE
!
• The location of the filters may differ, de-
pending on the model.
• The plasma filter may not be included in
some models.
• The feature can be changed according a
type of model.
TROUBLESHOOTING
19
ENGLISH
TROUBLESHOOTING
Self-diagnosis function
This product has a built-in self-diagnosis function. If an error occurs, the lamp of the indoor unit
will blink in 2 second intervals. If this occurs, contact your local dealer or service center.
Before requesting service
Please check the following before you contact the service center. If the problem persists, contact
your local service center.
Problem Possible causes Corrective action
There is a burning smell and
a strange sound coming
from the unit.
-
Turn off the air conditioner, unplug the
power cord and contact the service center.
Water leaks from the indoor
unit even when the humidity
level is low.
The power cord is damaged
or generating excessive
heat.
A switch, a circuit breaker
(safety, ground) or a fuse is
not operated properly.
The air conditioner does not
work.
The air conditioner is
unplugged.
Check whether the power cord is plugged
into the outlet.
A fuse is blown or the
power supply is
blocked.
Replace the fuse or check if the circuit
breaker has tripped.
A power failure has
occurred.
Turn off the air conditioner when a power
failure occurs. When the power is restored,
wait 3 minutes, and then turn on the air
conditioner.
The voltage is too
high or too low.
Check if the circuit breaker has tripped.
The air conditioner
turned off automati-
cally at a preset time.
Press the power button again.
20
TROUBLESHOOTING
ENGLISH
Problem Possible causes Corrective action
The air conditioner does not
generate cool air.
Air is not circulating
properly.
Make sure that there are no curtains,
blinds or furniture blocking the front of the
air conditioner.
The air filter is dirty.
Clean the air filter once every 2 weeks.
See “Cleaning Air Filter” for more infor-
mation.
The room tempera-
ture is too high.
In summer, it may take some time to cool
indoor air. In this case, select the jet cool
operation to cool indoor air quickly.
Cold air is escaping
from the room.
Make sure that no cold air is escaping
through ventilation points in the room.
The desired tempera-
ture is higher than the
set temperature.
Set the desired temperature to a level
lower than the current temperature.
There is a heating
source nearby.
Avoid using a heat generator such as an
electric oven or a gas burner while the air
conditioner is in operation.
Air circulation opera-
tion is selected.
In the air circulation operation, air blows
from the air conditioner without cooling or
heating the indoor air. Switch the opera-
tion mode to the cooling operation.
It is not possible to adjust
the fan speed.
The auto operation,
jet operation or dehu-
midifying operation is
selected.
In some operation modes, such as the jet
or dehumidifying operation modes, you
cannot adjust the fan speed. Select an op-
eration mode in which you can adjust the
fan speed.
It is not possible to adjust
the temperature.
The air circulation op-
eration or jet opera-
tion is selected.
In some operation modes, such as the air
circulation or jet operation mode, you can-
not adjust the temperature. Select an op-
eration mode in which you can adjust the
temperature.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

LG AMNW24GECA0 El kitabı

Kategori
Mobil klimalar
Tip
El kitabı
Bu kılavuz için de uygundur

Diğer dillerde