Beurer IH 21 Instructions For Use Manual

Tip
Instructions For Use Manual
IH 21
Beurer GmbH
Söflinger Str. 218
89077 Ulm, Germany
Tel.: +49 (0)731 / 39 89 -144
Fax: +49 (0)731 / 39 89 - 255
www.beurer.com
D
Inhalator
Gebrauchsanweisung ............ 2 – 10
G
Nebuliser
Instructions for use ...............11 – 18
F
Inhalateur
Mode d’emploi ...................... 19 – 27
E
Inhalador
Manual de instrucciones ...... 28 – 36
I
Inalatore
Istruzioni per l’uso ................ 37 – 45
T
Inhalatör
Kullanım kılavuzu .................. 46 – 53
r
Ингалятор
Инструкция по
применению ......................... 54 – 63
Q
Inhalator
Instrukcja obsługi ................. 64 – 72
ELECTROMAGNETIC COMPATIBILITY
INFORMATION
......................................73-76
0483
2
Inhalt
Lieferumfang
Siehe Geräte- und Zubehörbeschreibung Seite 4.
Inhalator
Vernebler
Druckluftschlauch
Mundstück
Erwachsenenmaske
Kindermaske
Nasenstück
Ersatzfilter
Diese Gebrauchsanweisung
1. Kennenlernen
Sehr geehrte Kundin, sehr geehrter Kunde,
wir freuen uns, dass Sie sich für ein Produkt unseres
Sortimentes entschieden haben. Unser Name steht für
hochwertige und eingehend geprüfte Qualitätsprodukte
aus den Bereichen Wärme, Gewicht, Blutdruck, Körper-
temperatur, Puls, Sanfte Therapie, Massage und Luft.
Bitte lesen Sie diese Gebrauchsanweisung aufmerk-
sam durch, bewahren Sie sie für späteren Gebrauch
auf, machen Sie sie anderen Benutzern zugänglich und
beachten Sie die Hinweise.
Mit freundlicher Empfehlung
Ihr Beurer-Team
Anwendungsbereich
Dieser Inhalator ist ein Inhalationsgerät zur Verneb-
lung von Flüssigkeiten und flüssigen Medikamenten
(Aerosolen) und für die Behandlung der oberen und
unteren Atemwege.
Durch Verneblung und Inhalation des vom Arzt verord-
neten bzw. empfohlenen Medikaments können Sie Er-
krankungen der Atemwege vorbeugen, deren Begleit-
erscheinungen mildern und die Heilung beschleunigen.
Weitere Auskünfte über die Einsatzmöglichkeiten erfah-
ren Sie durch Ihren Arzt oder Apotheker.
Das Gerät ist für die Inhalation zu Hause geeignet.
Die Medikamenteninhalation sollte nur nach ärztlicher
Anweisung erfolgen. Nehmen Sie die Inhalation ruhig
und entspannt vor und atmen Sie langsam und tief ein,
damit das Medikament bis in die feinen, tief liegenden
Bronchien gelangen kann. Atmen Sie normal aus.
Das Gerät ist nach Aufbereitung für den Wiederein-
satz geeignet. Die Aufbereitung umfasst den Austausch
sämtlicher Zubehörteile inklusive Vernebler und Luft-
filter sowie eine Geräteoberflächendesinfektion mit
einem handelsüblichen Desinfektionsmittel.
2. Zeichenerklärung
Folgende Symbole werden in der Gebrauchsanweisung
verwendet.
Warnung Warnhinweis auf Verletzungs-
gefahren oder Gefahren für Ihre
Gesundheit.
Achtung Sicherheitshinweis auf mögliche
Schäden am Gerät/Zubehör.
Hinweis
Hinweis auf wichtige Informationen.
Auf der Verpackung und auf dem Typenschild des
Gerätes und des Zubehörs werden folgende Symbole
verwendet.
Anwendungsteil Typ BF
Gebrauchsanweisung beachten
Gerät der Schutzklasse 2
H
ersteller
I
Ein
O
Aus
SN
Seriennummer
30 ON /
30 OFF
30 Minuten Betrieb, anschließend 30 Minu-
ten Pause vor erneutem Betrieb.
Vor Nässe schützen
3. Warn- und Sicherheitshinweise
Warnung
Vor dem Gebrauch ist sicherzustellen, dass das
Gerät und Zubehör keine sichtbaren Schäden auf-
weisen. Benutzen Sie es im Zweifelsfall nicht und
DEUTSCH
1. Kennenlernen.......................................................2
2. Zeichenerklärung .................................................2
3. Warn- und Sicherheitshinweise ...........................2
4. Geräte- und Zubehör beschreibung .....................4
5. Inbetriebnahme ...................................................5
6. Bedienung ...........................................................5
7. Filterwechsel ........................................................7
8. Reinigung und Desinfektion ................................7
9. Entsorgen ............................................................8
10. Problemlösung ....................................................9
11. Technische Angaben ...........................................9
12. Garantie und Service .........................................10
3
wenden Sie sich an Ihren Händler oder an die ange
-
gebene Kundendienstadresse.
Bei Störungen des Geräts bitte im Kapitel "10. Pro-
blemlösung" nachschauen.
Eine Anwendung des Gerätes ersetzt keine ärztliche
Konsultation und Behandlung. Befragen Sie bei je-
der Art von Schmerz oder Krankheit deshalb immer
zunächst Ihren Arzt.
Bei gesundheitlichen Bedenken irgendwelcher Art
konsultieren Sie Ihren Hausarzt!
Beachten Sie beim Einsatz des Verneblers die allge-
meinen Hygienemaßnahmen.
Für den Typ des zu verwendenden Medikamentes,
die Dosierung, die Häufigkeit und die Dauer der In-
halation sind immer die Anweisungen des Arztes zu
befolgen.
Verwenden Sie nur Medikamente, die von Ihrem Arzt
oder Apotheker verordnet oder empfohlen wurden.
Bitte beachten:
Für die Behandlung nur die vom Arzt entsprechend
der Krankheitslage angegebenen Teile verwenden.
Auf dem Beipackzettel des Medikaments kontrollie-
ren, ob Gegenanzeigen für den Gebrauch mit den
üblichen Systemen für Aerosoltherapie bestehen.
Sollte das Gerät nicht korrekt funktionieren, sich Un-
wohlsein oder Schmerzen einstellen, brechen Sie die
Anwendung sofort ab.
Halten Sie das Gerät während des Gebrauchs von Ih-
ren Augen entfernt, der Medikamentennebel könnte
schädigend wirken.
Betreiben Sie das Gerät nicht bei Vorhandensein von
brennbaren Gasen und hoher Sauerstoffkonzentra-
tion.
Dieses Gerät ist nicht dafür bestimmt, durch Kinder
oder Personen mit eingeschränkten physischen,
sensorischen (z.B. Schmerzunempfindlichkeit) oder
geistigen Fähigkeiten oder mangels Erfahrung und/
oder mangels Wissen benutzt zu werden. Es sei
denn, sie werden durch eine für Ihre Sicherheit zu-
ständige Person beaufsichtigt oder erhielten von ihr
Anweisungen, wie das Gerät zu benutzen ist.
Vor jedem Reinigungs- und/oder Wartungseingriff
muss das Gerät ausgeschaltet und der Stecker ab-
gezogen werden.
Halten Sie Kinder vom Verpackungsmaterial fern
(Erstickungsgefahr).
Zur Vermeidung der Gefahr des Verfangens und der
Strangulation, die Kabel und Luftleitungen außerhalb
der Reichweite von kleinen Kindern aufbewahren.
Benutzen Sie keine Zusatzteile, die nicht vom Her-
steller empfohlen werden.
Das Gerät darf nur an die auf dem Typschild ange-
gebene Netzspannung angeschlossen werden.
Tauchen Sie das Gerät nicht in Wasser und verwen-
den Sie es nicht in Nassräumen. Es dürfen keinesfalls
Flüssigkeiten in das Gerät eindringen.
Schützen Sie das Gerät vor stärkeren Stößen.
Fassen Sie die Netzleitung niemals mit nassen Hän-
den an, Sie könnten einen Stromschlag erleiden.
Den Netzstecker nicht an der Netzleitung aus der
Steckdose herausziehen.
Die Netzleitung nicht einklemmen, knicken, über
scharfkantige Gegenstände ziehen, nicht herunter-
hängen lassen sowie vor Hitze schützen.
Wir empfehlen, das Versorgungskabel vollständig
abzurollen, um ein gefährliches Überhitzen zu ver-
meiden.
Wenn die Netzanschlussleitung dieses Gerätes be-
schädigt wird, muss sie durch den Hersteller oder
seinen Kundendienst oder einer ähnlich qualifizierten
Person ersetzt werden, um Gefährungen zu vermei-
den.
Beim Öffnen des Gerätes besteht die Gefahr eines
elektrischen Schlages. Die Trennung vom Versor-
gungsnetz ist nur gewährleistet, wenn der Netzste-
cker aus der Steckdose gezogen ist.
Wenn das Gerät heruntergefallen ist, extremer Feuch-
tigkeit ausgesetzt wurde oder anderweitige Schäden
davongetragen hat, darf es nicht mehr benutzt wer-
den. Setzen Sie sich im Zweifelsfall mit dem Kunden-
service oder Händler in Verbindung.
Der IH 21 Inhalator darf nur mit dafür passenden
Beurer Verneblern und mit entsprechendem Beurer
Zubehör betrieben werden. Die Verwendung von
Fremdverneblern und -Zubehör kann zur Beeinträch-
tigung der Therapieeffizienz führen und gegebenen-
falls das Gerät beschädigen.
Achtung
Stromausfall, plötzliche Störungen bzw. andere un-
günstige Bedingungen könnten zur Betriebsunfä-
higkeit des Geräts führen. Deshalb wird empfohlen,
über ein Ersatzgerät bzw. ein (mit dem Arzt abge-
sprochenes) Medikament zu verfügen.
Sollten Adapter oder Verlängerungen erforderlich
sein, müssen diese den geltenden Sicherheitsvor-
schriften entsprechen. Die Stromleistungsgrenze
sowie die auf dem Adapter angegebene Maximallei-
stungsgrenze dürfen nicht überschritten werden.
Das Gerät und das Versorgungskabel darf nicht in
der Nähe von Wärmequellen aufbewahrt werden.
Das Gerät darf nicht in Räumen verwendet werden,
in denen zuvor Sprays verwendet wurden. Vor der
Therapie sind diese Räume zu lüften.
Keine Gegenstände in die Kühlungsöffnungen ge-
langen lassen.
4
Das Gerät nie verwenden, wenn es ein anormales
Geräusch verursacht.
Es ist aus hygienischen Gründen unbedingt erfor-
derlich, dass jeder Benutzer sein eigenes Zubehör
verwendet.
Nach dem Gebrauch immer den Netzstecker ziehen.
Das Gerät an einem vor Witterungseinflüssen ge-
schützten Ort aufbewahren. Das Gerät muss bei den
vorgesehenen Umgebungsverhältnissen aufbewahrt
werden.
SICHERUNG
Im Gerät befindet sich eine Überstromsicherung.
Diese darf nur vom autorisierten Fachpersonal ge-
wechselt werden.
Allgemeine Hinweise
Achtung
Verwenden Sie das Gerät ausschließlich:
am Menschen,
für den Zweck, für den es entwickelt wurde (Aero-
solinhalation) und auf die in dieser Gebrauchsan-
weisung angegebene Art und Weise.
Jeder unsachgemäße Gebrauch kann gefährlich
sein!
Bei akuten Notfällen hat die Erste Hilfe Vorrang.
Verwenden Sie neben den Medikamenten nur de-
stilliertes Wasser bzw. eine Kochsalzlösung. Andere
Flüssigkeiten führen unter Umständen zu einem De-
fekt des Inhalators bzw. Verneblers.
Dieses Gerät ist nicht für den gewerblichen oder kli-
nischen Gebrauch bestimmt, sondern ausschließlich
zur Eigenanwendung im privaten Haushalt!
Vor Inbetriebnahme
Achtung
Vor Gebrauch des Gerätes ist jegliches Verpackungs-
material zu entfernen.
Schützen Sie das Gerät vor Staub, Schmutz und
Feuchtigkeit, decken Sie das Gerät auf keinen Fall
während des Betriebes ab.
Betreiben Sie das Gerät nicht in stark staubbelasteter
Umgebung.
Schalten Sie das Gerät sofort aus, wenn es defekt
ist oder Betriebsstörungen vorliegen.
Der Hersteller haftet nicht für Schäden, die durch
unsachgemäßen oder falschen Gebrauch verursacht
wurden.
Reparatur
Hinweis
Sie dürfen das Gerät keinesfalls öffnen oder repa-
rieren, da sonst eine einwandfreie Funktion nicht
mehr gewährleistet ist. Bei Nichtbeachten erlischt
die Garantie.
Wenden Sie sich bei Reparaturen an den Kunden-
service oder an einen autorisierten Händler.
4. Geräte- und Zubehör-
beschreibung
Übersicht Inhalator
1
5
6
7
2
3
4
1 Netzanschlusskabel
2 Deckel
3 Ein-/Aus-Schalter
4 Fach für Zubehör
5 Filterkappe mit Filter
6 Schlauchanschluss
7 Halterung für Vernebler
5
Übersicht Vernebler und Zubehör
8 Druckluftschlauch
9 Vernebler
10 Verneblereinsatz
11 Ventil
12 Medikamentenbehälter
13 Mundstück
14 Erwachsenenmaske
15 Kindermaske
16 Nasenstück
17 Ersatzfilter
5. Inbetriebnahme
Aufstellen
Entnehmen Sie das Gerät der Verpackung.
Stellen Sie es auf einer ebenen Fläche auf.
Achten Sie darauf, dass die Lüftungsschlitze frei sind.
Klappen Sie den Deckel [2] auf, um an die Zubehörteile
zu gelangen.
Vor der ersten Verwendung
Hinweis
Vor der ersten Nutzung sollte der Vernebler und das
Zubehör gereinigt und desinfiziert werden. Siehe
hierzu „Reinigung und Desinfektion“ Seite 7.
Stecken Sie den Druckluftschlauch [8] unten an den
Medikamentenbehälter [12].
Stecken Sie das andere Ende des Schlauchs [8] mit
leichter Drehung in den Schlauchanschluss [6] des
Inhalators.
Netzanschluss
Das Gerät nur an die auf dem Typschild angegebene
Netzspannung anschließen.
Stecken Sie den Netzstecker des Netzkabels [1] in
eine geeignete Steckdose.
Zur Netzverbindung den Stecker vollständig in die
Steckdose stecken.
Hinweis
Achten Sie darauf, dass sich eine Steckdose in der
Nähe des Aufstellplatzes befindet.
Verlegen Sie das Netzkabel so, dass niemand darü-
ber stolpern kann.
Zur Trennung des Inhalators vom Stromnetz nach
der Inhalation schalten Sie zuerst das Gerät aus und
ziehen Sie dann den Netzstecker aus der Steckdose.
6. Bedienung
Achtung
Aus hygienischen Gründen ist es unbedingt erforder-
lich den Vernebler [9] sowie das Zubehör nach jeder
Behandlung zu reinigen und nach der täglich letzten
Behandlung zu desinfizieren.
Die Zubehörteile dürfen nur von einer Person benutzt
werden; vom Gebrauch durch mehreren Personen
wird abgeraten.
Sollten bei der Therapie mehrere verschiedene Medi-
kamente nacheinander inhaliert werden, so ist zu
beachten, dass der Vernebler [9] nach jeder Anwen-
dung unter warmem Leitungswasser durchgespült
wird. Siehe hierzu „Reinigung und Desinfektion“ auf
Seite 7.
Beachten Sie die Hinweise zum Filterwechsel in die-
ser Anleitung!
Überprüfen Sie vor jeder Verwendung des Gerätes
den festen Sitz der Schlauchanschlüsse am Inhalator
[6] und am Vernebler [9].
8
9
10
11
12
13
14
17
16
15
6
Prüfen Sie vor der Benutzung das Gerät auf ord-
nungsgemäße Funktion, hierfür schalten Sie den
Inhalator (samt angeschlossenem Vernebler, aber
ohne Medikamente) für einen kurzen Moment ein.
Wenn hierbei Luft aus dem Vernebler [9] kommt,
funktioniert das Gerät.
1. Düsenaufsatz einsetzen
Öffnen Sie den Vernebler [9], indem Sie das Oberteil
im Gegenuhrzeigersinn gegen den Medikamenten-
behälter [12] drehen. Setzen Sie den Düsenaufsatz
[10] in den Medikamentenbehälter [12] ein.
Stellen Sie sicher, dass der Kegel für die Medikamen-
tenführung gut auf dem Kegel für die Luftführung im
Innern des Zerstäubers aufsitzt.
2. Vernebler befüllen
Füllen Sie eine isotonische Koch-
salzlösung oder das Medikament
direkt in den Medikamentenbehäl-
ter [12]. Vermeiden Sie eine Über-
füllung! Die maximal empfohlene
Füllmenge beträgt 8 ml !
Verwenden Sie Medikamente nur
auf Anweisung Ihres Arztes und
fragen Sie nach der für Sie ange-
messenen Inhalationsdauer und
-menge!
Liegt die vorgegebene Menge des Medikamentes
bei weniger als 2 ml, füllen Sie diese Menge mit
isotonischer Kochsalzlösung auf mind. 4 ml auf. Ei-
ne Verdünnung ist bei zähflüssigen Medikamenten
ebenfalls notwendig. Achten Sie auch hier auf die
Anweisung Ihres Arztes.
3. Vernebler schließen
• Schließen Sie den Vernebler [9], indem Sie das Ober-
teil im Uhrzeigersinn gegen den Medikamentenbe-
hälter [12] drehen. Achten Sie auf korrekte Verbin-
dung!
4. Ventil einsetzen
Drücken Sie das blaue Ventil [11] in die dafür vorge-
sehene Öffnung an der Oberseite des Verneblers [9].
Hinweis
Das Ventilsystem gewährleistet eine verbesserte Lun-
gengängigkeit des Medikaments. Das Ventil [11] nur
mit dem Mundstück [13] verwenden, niemals mit den
Masken [14,15] oder dem Nasenstück [16] verwenden.
5. Zubehör mit Vernebler verbinden
Vernebler [9] mit gewünschtem Zubehör (Mundstück
[13], Erwachsenenmaske [14], Kindermaske [15] oder
Nasenstück [16]) verbinden.
Hinweis
Die Inhalation mit dem Mundstück ist die wirksamste
Form der Therapie. Der Gebrauch der Maskeninhala
-
tion wird nur empfohlen, wenn die Verwendung eines
Mundstücks nicht möglich ist (z.B. bei Kindern die
noch nicht mit dem Mundstück inhalieren können).
Ziehen Sie den Vernebler vor der Behandlung nach
oben aus der Halterung [7] heraus.
Starten Sie den Inhalator mit dem Ein-/Aus-Schalter [3].
• Das Ausströmen des Sprühnebels aus dem Vernebler
zeigt den einwandfreien Betrieb.
6. Behandlung
Während des Inhalierens aufrecht und entspannt an
einem Tisch und nicht in einem Sessel sitzen, um
die Atemwege nicht zusammenzudrücken und so
die Wirksamkeit der Bahandlung zu Beeinträchtigen.
Atmen Sie das zerstäubte Medikament tief ein.
Achtung
Das Gerät ist nicht für Dauerbetrieb geeignet, nach
30 Minuten Betrieb muss es 30 Minuten abgeschaltet
werden.
Hinweis
Halten Sie den Vernebler während der Behandlung ge-
rade (senkrecht), da ansonsten die Zerstäubung nicht
funktioniert und eine einwandfreie Funktion nicht ge
-
währleistet ist.
Achtung
Ätherische Heilpflanzenöle, Hustensäfte, Lösungen zum
Gurgeln, Tropfen zum Einreiben oder für Dampfbäder
sind grundsätzlich ungeeignet für die Inhalation mit In
-
halatoren. Diese Zusätze sind oft zähflüssig und können
die korrekte Funktion des Gerätes und damit die Wirk-
samkeit der Anwendung nachhaltig beeinträchtigen.
Bei einer Überempfindlichkeit des Bronchialsystems
können Medikamente mit ätherischen Ölen unter Um-
ständen einen akuten Bronchospasmus (eine plötzliche
krampfartige Einengung der Bronchien mit Atemnot)
auslösen. Fragen Sie dazu Ihren Arzt oder Apotheker!
7. Inhalation beenden
Tritt der Nebel nur noch unregelmäßig aus oder verän-
dert sich das Geräusch bei der Inhalation können Sie
die Behandlung beenden.
Schalten Sie den Inhalator nach der Behandlung mit
dem Ein-/Aus-Schalter [3] aus und trennen Sie ihn
vom Stromnetz.
Setzen Sie den Vernebler [9] nach der Behandlung
wieder zurück in seine Halterung [7].
10
11
12
7
8. Reinigung durchführen
Siehe „Reinigung und Desinfektion“ auf Seite 7.
7. Filterwechsel
Bei normalen Benutzungsbedingungen ist der Luftfil-
ter nach etwa 500 Betriebsstunden bzw. einem Jahr
auszutauschen. Kontrollieren Sie den Luftfilter bitte
regelmäßig (nach 10-12 Zerstäubungsvorgängen).
Ist er stark verschmutzt oder verstopft, wechseln Sie
den gebrauchten Filter aus. Sollte der Filter feucht
geworden sein, muss er ebenfalls gegen einen neuen
Filter ausgewechselt werden.
Achtung
Versuchen Sie nicht, den gebrauchten Filter zu rei-
nigen und wieder zu verwenden!
Benutzen Sie ausschließlich den Original-Filter des
Herstellers, da ansonsten Ihr Inhalator beschädigt
werden könnte oder keine ausreichend effektive The-
rapie sichergestellt werden kann.
Der Luftfilter darf nicht repariert oder gewartet wer-
den, während er bei einer Person im Einsatz ist.
Gerät niemals ohne Filter betreiben.
Zum Auswechseln des Filters gehen Sie folgender-
maßen vor:
Achtung
Gerät erst ausschalten und vom Netz trennen.
Gerät abkühlen lassen.
1. Filterkappe [5] nach oben
abziehen.
Hinweis
Falls der Filter nach Abziehen der Kappe im Gerät ver-
bleibt, entfernen Sie den Filter, z.B. mit einer Pinzette
oder Ähnlichem, aus dem Gerät.
2. Filterkappe [5] mit neuem Filter wieder einsetzen.
3. Festen Sitz prüfen.
8. Reinigung und Desinfektion
Vernebler und Zubehör
Warnung
Befolgen Sie nachfolgende Hygienevorschriften, um
eine Gesundheitsgefährdung zu vermeiden.
Vernebler [9] und Zubehör sind für eine Mehrfach-
verwendung vorgesehen. Bitte beachten Sie, dass
für die unterschiedlichen Anwendungsbereiche
verschiedene Anforderungen an die Reinigung und
hygienische Wiederaufbereitung gestellt werden.
Hinweise:
Eine mechanische Reinigung des Verneblers sowie
des Zubehörs mit Bürsten oder der Gleichen, muss
unterbleiben, da hierbei irreparable Schäden die Fol-
ge sein können und ein gezielter Behandlungserfolg
nicht mehr gewährleistet ist.
Die zusätzlichen Anforderungen bezüglich der not-
wendigen hygienischen Vorbereitung (Handpflege,
Handhabung der Medikamente bzw. der Inhalations-
lösungen) bei Hochrisikogruppen (z.B. Mukoviszido-
sepatienten) erfragen Sie bitte bei Ihrem Arzt.
Achten Sie auf ausreichende Trocknung nach jeder
Reinigung, Desinfektion. Eine Restfeuchtigkeit bzw.
Restnässe kann ein erhöhtes Risiko für Keimwachs-
tum darstellen.
Vorbereitung
Direkt nach jeder Behandlung
müssen alle Teile des Verneblers
[9] sowie das benutzte Zubehör
von Medi kamentenresten und
Verunreinigungen gereinigt wer
-
den.
Hierfür zerlegen Sie den Vernebler
[9] in seine Einzel teile.
Ziehen Sie das Mundstück [13],
die Maske [14, 15] oder das Na-
senstück [16] vom Vernebler ab.
Zerlegen Sie den Vernebler, indem Sie das Oberteil
im Gegenuhrzeigersinn gegen den Medikamenten
-
behälter [12] drehen.
Entfernen Sie den Düsenaufsatz [10] aus dem
Medikamentenbehälter [12].
Entfernen Sie das Ventil [11] indem Sie es aus dem
Vernebler [9] heraus ziehen.
Der Zusammenbau erfolgt später sinngemäß in
umgekehrter Reihenfolge.
Reinigung
Achtung
Vor jeder Reinigung muss das Gerät ausgeschaltet,
vom Netz getrennt und abgekühlt sein.
Der Vernebler sowie das benutzte Zubehör wie Mund-
stück, Maske, Düsenaufsatz usw. müssen nach jeder
Anwendung mit heißem nicht kochendem Wasser ge
-
reinigt werden. Trocknen Sie die Teile sorgfältig mit
einem weichen Tuch ab. Setzen Sie die Teile, wenn
diese vollständig getrocknet sind, wieder zusammen
und legen Sie die Teile in ein trockenes, abgedichtetes
Behältnis oder führen Sie die Desinfektion durch.
Vergewissern Sie sich bei der Reinigung, dass jegliche
Rückstände entfernt werden. Verwenden Sie dabei auf
keinen Fall Substanzen, die bei der Berührung mit der
10
11
12
8
Haut oder den Schleimhäuten, verschluckt oder inha
-
liert potenziell giftig sein könnten.
Benutzen Sie zur Reinigung des Gerätes ein weiches,
trockenes Tuch und ein nicht scheuernds Reinigungs-
mittel.
Benutzen Sie keine scharfen Reinigungsmittel und hal-
ten Sie das Gerät niemals unter Wasser.
Achtung
Achten Sie darauf, dass kein Wasser in das Geräte-
innere gelangt!
Gerät und Zubehör nicht in der Spülmaschine reini-
gen!
Das Gerät darf im angeschlossenen Zustand nicht
mit feuchten Händen angefasst werden; es darf kein
Wasser auf das Gerät spritzen. Das Gerät darf nur im
vollständig trockenen Zustand betrieben werden.
Sprühen Sie keine Flüssigkeit in die Lüftungsschlitze!
Eingedrungene Flüssigkeiten können eine Beschä-
digung der Elektrik sowie anderer Inhalatorteile ver-
ursachen und zu einer Funktionsstörung führen.
Kondenswasser, Schlauchpflege
Je nach Umgebungsbedingungen kann sich im
Schlauch Kondenswasser absetzen. Um Keimwachs-
tum vorzubeugen und eine einwandfreie Therapie zu
gewährleisten, ist die Feuchtigkeit unbedingt zu entfer-
nen. Gehen Sie dazu folgendermaßen vor:
Ziehen Sie den Schlauch [8] vom Vernebler [9] ab.
Lassen Sie den Schlauch inhalatorseitig [6] einge-
steckt.
Nehmen Sie den Inhalator so lange in Betrieb, bis
die Feuchtigkeit durch die durchströmende Luft
beseitigt ist.
Bei starken Verschmutzungen ersetzen Sie den
Schlauch.
Desinfektion
Bitte folgen Sie den unten aufgeführten Punkten sorg-
fältig, um Ihren Vernebler und das Zubehör zu desin-
fizieren. Es wird empfohlen die Einzelteile spätestens
nach der täglich letzten Benutzung zu desinfizieren.
(Sie benötigen hierzu lediglich ein wenig farblosen
Essig und destilliertes Wasser!)
Reinigen Sie zunächst den Vernebler und das Zube-
hör wie unter „Reinigung“ beschrieben.
• Den zerlegten Zerstäuber, das Mundstück und das
Nasenstück 5 Minuten lang in kochendes Wasser
legen.
Für das übrige Zubehör benutzen Sie eine Essigmi
-
schung bestehend aus ¼ Essig und ¾ destilliertem
Wasser. Stellen Sie sicher, dass die Menge ausrei
-
chend ist, dass die Teile wie Vernebler, Maske und
Mundstück vollständig darin eingetaucht werden
können.
Belassen Sie die Teile für 30 Minuten in der Essigmi-
schung.
Spülen Sie die Teile mit Wasser aus und trocknen
Sie diese sorgfältig mit einem weichen Tuch ab.
Achtung
Masken und Luftschlauch nicht abkochen oder au-
toklavieren.
Setzen Sie die Teile wenn diese vollständig getrock-
net sind wieder zusammen und legen Sie die Teile in
ein trockenes, abgedichteten Behältnis.
Hinweis
Bitte beachten Sie, dass die Teile nach der Reinigung
vollständig getrocknet werden, da an sonsten hier das
Risiko von Keimwachstum erhöht ist.
Sterilisierung
Kaltsterilisierungslösungen gemäß Herstelleranwei-
sung benutzen.
Trocknung
Legen Sie die Einzelteile auf eine trockene, saubere
und saugfähige Unterlage und lassen Sie sie voll-
ständig trocknen (mindestens 4 Stunden).
Materialbeständigkeit
Vernebler und Zubehör unterliegen bei häufiger
Anwendung und hygienischer Wiederaufbereitung,
wie jedes andere Kunststoffteil auch, einer gewis-
sen Abnutzung. Dies kann im Laufe der Zeit zu einer
Veränderung des Aerosols und somit auch zu einer
Beeinträchtigung der Therapieeffizienz führen. Wir
empfehlen deshalb den Vernebler nach einem Jahr
auszuwechseln.
Bei der Wahl der Reinigungs- bzw. Desinfektions-
mittel ist folgendes zu beachten: Verwenden Sie nur
ein mildes Reinigungsmittel oder Desinfektionsmittel,
welches Sie nach Herstellerangaben dosieren.
Aufbewahrung
Nicht in Feuchträumen (z.B. Badezimmer) lagern und
zusammen mit feuchten Gegenständen transportie-
ren.
Vor anhaltender direkter Sonneneinstrahlung ge-
schützt lagern und transportieren.
Die Zubehörteile können im Zubehörfach [4] sicher
verstaut werden. Das Gerät an einem trockenen
Platz, am besten in der Verpackung, aufbewahren.
9. Entsorgen
Im Interesse des Umweltschutzes darf das
Gerät nicht mit dem Hausmüll entsorgt werden.
9
Bitte entsorgen Sie das Gerät gemäß der Elektro- und
Elektronik Altgeräte EG-Richtlinie – WEEE (Waste Elec-
trical and Electronic Equipment).
Bei Rückfragen wenden Sie sich bitte an die für die
Entsorgung zuständige kommunale Behörde.
10. Problemlösung
Probleme/
Fragen
Mögliche Ursache/Behebung
Der Vernebler
erzeugt kein
oder zu wenig
Aerosol.
1. Zuviel oder zuwenig Medikament
im Vernebler.
Minimum: 2 ml,
Maximum: 8 ml.
2. Düse auf Verstopfung prüfen.
Gegebenenfalls Düse reinigen
(z.B. durch Ausspülen). Ver
-
nebler danach erneut in Betrieb
nehmen.
ACHTUNG: die feinen Bohrungen
nur von der Düsenunterseite vor
-
sichtig durchstechen.
3. Vernebler nicht senkrecht
gehalten.
4. Ungeeignete Medikamentenflüs-
sigkeit zum Vernebeln eingefüllt
(z.B. zu dickflüssig).
Die Medikamentenflüssigkeit sollte
vom Arzt vorgegeben werden.
Der Ausstoß
ist zu gering.
Geknickter Schlauch, verstopfter
Filter, zu viel Inhalationslösung.
Welche
Medikamente
kann man
inhalieren?
Bitte fragen Sie hierzu Ihren Arzt.
Grundsätzlich können alle Medika-
mente, die für eine Geräte-Inhala-
tion geeignet und zugelassen sind,
inhaliert werden.
Es bleibt
Inhalations
-
lösung im
Vernebler
zurück.
Dies ist technisch bedingt und
normal. Beenden Sie die Inhalation,
sobald Sie ein deutlich verändertes
Verneblergeräusch hören.
Was ist bei
Babys und
Kindern zu
beachten?
1. Bei Babys sollte die Maske
Mund und Nase abdecken
um eine effektive Inhalation zu
gewährleisten.
2. Bei Kindern sollte ebenfalls
die Maske Mund und Nase
abdecken. Eine Verneblung
neben schlafenden Personen ist
wenig sinnvoll, da hierbei nicht
genügend des Medikaments in
die Lunge gelangen kann.
Probleme/
Fragen
Mögliche Ursache/Behebung
Hinweis: es sollte nur unter
Aufsicht und mit Hilfe einer er
-
wachsenen Person inhaliert werden
und das Kind nicht allein gelassen
werden.
Die Inhalation
mit der Maske
dauert län
-
ger?
Dies ist technisch bedingt. Durch
die Maskenlöcher atmen Sie pro
Atemzug weniger Medikament
ein als über das Mundstück. Das
Aerosol wird über die Löcher mit
Raumluft vermischt.
Warum soll
der Vernebler
regelmäßig
ausgewech
-
selt werden?
Dafür gibt es zwei Gründe:
1. Um ein therapeutisch wirksames
Teilchenspektrum zu gewähr
-
leisten, soll die Düsenbohrung
einen bestimmten Durch
-
messer nicht überschreiten.
Bedingt durch mechanische
und thermische Beanspru
-
chung unterliegt der Kunststoff
einem gewissen Verschleiß. Der
Düsenaufsatz [10] ist besonders
sensibel. Damit kann sich auch
die Tröpfchenzusammensetzung
des Aerosols verändern, was
unmittelbar die Effektivität der
Behandlung beeinflusst.
2. Zudem wird ein regelmäßiger
Wechsel des Verneblers aus hy
-
gienischen Gründen empfohlen.
Benötigt
jeder seinen
eigenen
Vernebler?
Aus hygienischer Sicht ist dies
unbedingt notwendig.
11. Technische Angaben
Model
IH 21
Type
IH 21/1
Abmessungen
(BxHxT) 300 x 180 x 100 mm
Gewicht
1,65 kg
Arbeitsdruck ca. 0,8 - 1,45 bar
Füllvolumen
Vernebler
max. 8 ml
min. 2 ml
Medikamenten
-
fluss ca. 0,3 ml/min.
Schalldruck max. 52 dBA
(gem. DIN EN 13544-1 Abschnitt 26)
Netzanschluss 230 V~; 50 Hz; 230 VA
UK: 240 V~; 50 Hz; 240 VA
10
Betriebs-
bedingungen
Temperatur: +10 °C bis +40 °C
Relative Luftfeuchte: 10% bis 95%
Lager-und Trans
-
portbedingungen
Temperatur: 0 °C bis +60 °C
Relative Luftfeuchte: 10% bis 95%
Umgebungsdruck: 500 bis 1060 hPa
Aerosol
Eigenschaften
1) Durchfluss: 5,3 l/min
2) Aerosolabgabe: 0,216 ml
3) Aerosolabgaberate: 0,112 ml/min
4) Partikelgröße (MMAD): 3,85 µm
Technische Änderungen vorbehalten.
Diagramm Partikelgrößen
Die Messungen wurden mit einer Natrium-Fluorid-
Lösung mit einem "Next Generation Impactor" (NGI)
durchgeführt.
Das Diagramm ist möglicherweise so nicht auf Suspen-
sionen oder sehr zähflüssige Medikamente anwendbar.
Nähere Informationen dazu können Sie vom jeweiligen
Medikamentenhersteller erfahren.
Nachkaufartikel
Bezeichnung Material REF
Vernebler-Stopper PP
162.819
Yearpack (enthält Mundstück,
Nasenstück, Erwachsenen-
maske, Kinder maske,
Vernebler, Druckluftschlauch,
Filter)
PP/ PVC 601.22
Hinweis
Bei Verwendung des Gerätes außerhalb der Spezifi-
kation ist eine einwandfreie Funktion nicht gewährlei-
stet! Technische Änderungen zur Verbesserung und
Weiterentwicklung des Produktes behalten wir uns
vor. Dieses Gerät und dessen Zubehör entspricht den
europäischen Normen EN60601-1 und EN60601-1-2
sowie EN13544-1 und unterliegt besonderen Vorsichts-
maßnahmen hinsichtlich der elektromagnetischen Ver-
träglichkeit. Bitte beachten Sie dabei, dass tragbare
und mobile HF-Kommunikationseinrichtungen dieses
Gerät beeinflussen können. Genauere Angaben können
Sie unter der angegebenen Kundenservice-Adresse
anfordern oder am Ende der Gebrauchsanleitung nach-
lesen. Das Gerät entspricht den Anforderungen der
europäischen Richtlinie für Medizinprodukte 93/42/EC,
dem Medizinproduktegesetz.
ELEKTROMAGNETISCHE KOMPATIBILITÄT
Das Gerät entspricht den zur Zeit geltenden Vor-
schriften in Bezug auf die elektromagnetische Kom-
patibilität und ist geeignet für die Verwendung in
sämtlichen Gebäuden, einschließlich derjenigen, die
für private Wohnzwecke bestimmt sind. Die Radio-
frequenzemissionen des Geräts sind äußerst niedrig
und verursachen mit größter Wahrscheinlichkeit kei-
ne Interferenzen mit anderen Geräten in der Nähe.
Es empfiehlt sich auf jeden Fall, das Gerät nicht über
oder nahe bei anderen Geräten aufzustellen. Sollte es
mit Ihren Elektrogeräten zu Interferenzen kommen,
verstellen Sie es oder schließen Sie es an eine andere
Steckdose an.
Funkgeräte könnten den Betrieb des Geräts beein-
flussen.
12. Garantie und Service
Wir gewähren 3 Jahre Garantie auf Material und Fabri-
kationsfehler des Produktes.
Die Garantie gilt nicht:
im Falle von Schäden, die auf unsachgemäßer Be-
dienung beruhen,
für Verschleißteile (z.B. Vernebler, Filter, Druckluft-
schlauch etc.),
für Mängel, die dem Kunden bereits bei Kauf bekannt
waren,
bei Eigenverschulden des Kunden.
Die gesetzlichen Gewährleistungen des Kunden blei
-
ben durch die Garantie unberührt.
Für Geltendmachung eines Garantiefalles innerhalb der
Garantiezeit ist durch den Kunden der Nachweis des
Kaufes zu führen.
Die Garantie ist innerhalb eines Zeitraumes von 3 Jah-
ren ab Kaufdatum gegenüber der Beurer GmbH, Söf-
linger Straße 218, 89077 Ulm, Deutschland, geltend
zu machen. Der Kunde hat im Garantiefall das Recht
zur Reparatur der Ware bei unserem eigenen oder bei
von uns autorisierten Werkstätten. Weitergehende
Rechte werden dem Kunden (aufgrund der Garantie)
nicht eingeräumt.
11
Contents
Included in delivery
For details of the delivery scope, see description of the
device and accessories on page 13.
Nebuliser
Atomiser
Compressed air hose
Mouthpiece
Adult mask
Child mask
Nosepiece
Spare filter
These instructions for use
1. Getting to know your instrument
Dear customer
Thank you for choosing one of our products. Our name
stands for high-quality, thoroughly tested products for
applications in the areas of heat, weight, blood pres-
sure, body temperature, pulse, gentle therapy, mas-
sage and air.
Please read these instructions for use carefully and
keep them for later use, be sure to make them ac-
cessible to other users and observe the information
they contain.
With kind regards
Your Beurer team
Area of application
This nebuliser is a device used for the nebulisation
of liquids and liquid medication (aerosols) and for the
treatment of the upper and lower respiratory tract.
The nebulisation and inhalation of medication pre-
scribed or recommended by a doctor can prevent
against diseases of the respiratory tract, treat the side
effects of these disorders and accelerate healing.
For more information on possible applications, consult
your doctor or pharmacist.
The device is suitable for inhalation at home. Medicines
should only be inhaled when instructed by a doctor.
Inhalation should be performed in a calm and relaxed
atmosphere. Inhale slowly and deeply to enable the
medicine to reach the small bronchi deep into the
lungs. Exhale normally.
Once prepared, the device is suitable for reuse. The
preparation includes the replacement of all accessory
parts including atomiser and air filter, as well as disin
-
fection of the surfaces of the device with a standard
disinfectant.
2. Signs and symbols
The following symbols appear in these instructions.
Warning Warning instruction indicating a
risk of injury or damage to health.
Important Safety note indicating possible
damage to the unit/accessory.
Note
Note on important information.
The following symbols are used on the packaging and
on the nameplate of the device and accessories.
Type BF applied part
Read the instructions for use
Device in protection class 2
M
anufacturer
I
On
O
Off
SN
Serial number
30 ON /
30 OFF
30 minute operation, followed by a 30
minute break before operation continues.
Protect from moisture
3. Safety information and warnings
Warning
Before use, ensure that there is no visible damage to
the unit or accessories. When in doubt, do not use
the unit and contact your dealer or the customer
service address provided.
In the event of device faults, please see Chapter "10.
Troubleshooting".
ENGLISH
1. Getting to know your instrument .......................11
2. Signs and symbols ............................................11
3. Safety information and warnings ....................... 11
4. Description of device and accessories..............13
5. Initial use............................................................13
6. Operation ........................................................... 14
7.Changing the filter ..............................................15
8. Cleaning and disinfection ..................................15
9. Disposal ............................................................. 17
10. Troubleshooting .................................................17
11. Technical specifications ....................................18
12
Using the unit is not a substitute for consultation with
or treatment from a physician. Whenever you have
any pain or illness, always contact your physician
first.
If you have health concerns of any kind, contact your
general practitioner!
When using the atomiser, always follow the basic
hygiene procedures.
Always follow your doctor’s instructions regarding
the type of medicine to be used and the dose, fre-
quency, and duration of inhalation.
Only use medicines that have been prescribed or
recommended by your doctor or pharmacist.
Please note:
For treatment, only use parts indicated by your doc-
tor according to the particular diagnosis.
Check whether there are contraindications for use
with the usual systems for aerosol therapy on the
medication instruction leaflet.
If the unit does not function correctly or if you begin
to feel unwell or feel pain, stop using the unit im-
mediately.
During use, hold the unit away from the eyes, as
some nebulised medicines may cause damage to
the eyes.
Do not operate the unit in the presence of flammable
gases.
This device is not intended to be used by children
or persons with restricted physical, sensory (e.g.
insensitivity to pain) or mental abilities or persons
lacking in the required experience or knowledge for
safe operation of the device, unless supervised or
instructed by a person responsible for their safety.
The device must be switched off and the plug pulled
out before every cleaning and/or maintenance pro-
cedure.
Keep children away from packaging materials (risk
of suffocation).
To avoid the risk of entanglement and strangulation,
store cables and air lines out of the reach of small
children.
Do not use attachments that are not recommended
by the manufacturer.
Connect the unit only to the mains voltage listed on
the type plate.
Do not dip the unit into water and do not use it in wet
rooms. Do not allow any liquid to penetrate the unit.
Protect the unit from strong impacts.
Never touch the mains cable with wet hands, this
can cause an electric shock.
Do not pull the mains plug from the socket by the
cord.
Do not pinch or bend the mains cable, pull it over
sharp objects, or allow it to hang freely, and protect
it against sources of heat.
We recommend that the power cable is completely
unrolled to avoid dangerous overheating.
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, its
customer service department or a simi-larly qualified
person to avoid any risk.
Opening the unit carries a risk of electric shock. Dis-
connection from the mains supply is only guaranteed
if the mains plug has been removed from the socket.
Do not use the unit if it has fallen or been dropped
on the floor, been exposed to extreme humidity or
is otherwise damaged. In case of doubt, contact our
customer service department or your local dealer.
The IH 21 nebuliser must only be used with suitable
atomisers and with the appropriate accessories. The
use of other atomisers and accessories can impair
therapeutic efficiency and may damage the device.
Important
Power cuts, sudden faults or other unfavourable
conditions may render the unit unusable. You are
therefore recommended to keep a spare device or
replacement medicine (as agreed with the doctor).
If adapters or extensions are required, these must
comply with the applicable safety regulations. The
electrical capacity and the maximum capacity speci-
fied on the adapter must not be exceeded.
The unit and the mains cable must be stored away
from sources of heat.
Do not use the unit in a room in which a spray has
previously been used. If this is the case, ventilate the
room before commencing treatment.
Do not allow any objects to enter or obstruct the
ventilation openings.
Do not use the device if you notice an unusual noise.
For hygiene reasons, each user must use his own
accessories.
Always disconnect from the mains after use.
Store the device in a location protected against en-
vironmental influences. The device must be stored
in the specified ambient conditions.
FUSE
The device contains an overload protection fuse.
This must only be changed by authorised specialist
personnel.
General notes
Important
Use the unit only:
On humans,
for its intended purpose (aerosol inhalation) and in
the manner described in these instructions for use.
Any improper use can be dangerous!
13
In acute emergencies, first aid takes priority.
Apart from the medication, use only distilled water or
a saline solution in the unit. Other liquids may cause
defects to the nebuliser or atomiser.
This unit is not intended for commercial or clinical
use, but only for individual, private household use!
Before using the unit for the first time
Important
Before you use the unit for the first time, remove all
packaging materials.
Protect the unit against dust, dirt and moisture.
Never cover the unit during operation.
Do not use the unit in very dusty environments.
Switch the unit off immediately if it is defective or
malfunctioning.
The manufacturer shall not be held liable for damage
or injuries caused by improper or incorrect use.
Repairs
Note
Never open or attempt to repair the unit yourself, as
otherwise proper function is no longer guaranteed. Fail-
ure to observe this regulation shall void the warranty.
If you need to have the unit repaired, contact cus-
tomer service or an authorised dealer.
4. Description of device and
accessories
Overview of the nebuliser
1
5
6
7
2
3
4
1 Mains cable
2 Lid
3 On/off switch
4 Compartment for accessories
5 Filter cap with filter
6 Hose connection
7 Holder for atomiser
Overview of atomiser and accessories
8 Compressed air hose
9 Atomiser
10 Atomiser insert
11 Valve
12 Medicine container
13 Mouthpiece
14 Adult mask
15 Child mask
16 Nosepiece
17 Replacement filter
5. Initial use
Setup
Remove the unit from the packaging. Place it on a flat
surface.
Ensure that the ventilation slits are free.
Fold open the lid [2] to access the accessories.
Before using the unit for the first time
Note
The atomiser and accessories must be cleaned and
disinfected before they are used for the first time. For
information about this, see “Cleaning and disinfec-
tion” on page 15.
Attach the compressed-air hose [8] at the bottom of
the medicine container [12].
8
9
10
11
12
13
14
17
16
15
14
Connect the other end of the hose [8] to the hose
connector [6] on the nebuliser by lightly turning it.
Mains connection
Connect the unit only to the mains voltage listed on
the type plate.
Insert the mains cable plug [1] into a suitable socket.
Push the plug completely into the mains socket.
Note
Ensure that there is a socket near to where the unit
will stand.
Lay the mains cable in such a way that no one can
trip over it.
To disconnect the nebuliser from the mains after use,
first switch off the device and then remove the plug
from the socket.
6. Operation
Caution
For hygiene reasons, the atomiser [9] and the ac-
cessories must be cleaned after each treatment and
disinfected after the last treatment of the day.
The accessories may be used only by one person;
use by several people is not recommended.
If several different medicines are to be inhaled in suc-
cession during therapeutic use, the atomiser [9] must
be rinsed under warm tap water after each use. For
information about this, see “Cleaning and disinfec
-
tion” on page 15.
Follow the instructions for changing the filter con-
tained in these instructions.
Before each use, check that the hose connections
on the nebuliser [6] and the atomiser [9] are tight.
Before use, check that the device is functioning cor-
rectly. To do this, switch on the nebuliser (including
the connected atomiser, but without any medication)
for a short time. If the atomiser [9] expels air, the
device is functioning correctly.
1. Inserting the nozzle attachment
• To open the atomiser [9], twist the upper section anti-
clockwise against the medicine container [12]. Place
the nozzle attachment [10] in the medicine container
[12].
Ensure that the cone for administering medication fits
well on the cone for the air duct inside the nebuliser.
2. Filling the atomiser
Pour an isotonic saline solution
or the medicine directly into the
medicine container [12]. Do not
overfill! The maximum recom
-
mended fill level is 8 ml !
• Use medication only on the advice
of a physician, and check the ap-
propriate inhalation duration and
quantity for your needs.
If the required volume of medi-
cation is less than 2 ml, top up this quantity to at
least 4 ml using an isotonic saline solution. Viscous
medicines may also require dilution. Always follow
the instructions of your doctor.
3. Closing the atomiser
To close the atomiser [9], twist the upper section
clockwise against the medicine container [12]. En-
sure the parts are connected correctly.
4. Inserting the valve
• Press the blue valve [11] into the opening intended
for this purpose on the upper side of the atomiser
[9].
Note
The valve system ensures better delivery of the medi-
cation to the lungs. Only use the valve [11] with the
mouthpiece [13], never with the masks [14, 15] or the
nosepiece [16].
5. Connecting the accessories to the atomiser
Connect the required accessory part (mouthpiece
[13], adult mask [14], child mask [15] or nosepiece
[16]) to the atomiser [9].
Note
The most effective form of nebulisation is by using the
mouthpiece. Nebulisation using a mask is only recom-
mended if it is not possible to use a mouthpiece (e.g.
for children who are not yet able to inhale medication
using a mouthpiece).
Before commencing treatment, pull the atomiser
upwards out of its holder [7].
Start the nebuliser using the on/off switch [3].
10
11
12
15
A flow of spray from the atomiser indicates that the
device is functioning properly.
6. Treatment
When inhaling, sit upright and relaxed at a table and
not in an armchair to avoid compressing the airways
and therefore impairing the effectiveness of the treat-
ment.
Inhale the nebulised medicine deeply.
Important
The device is not suitable for continuous operation;
after 30 minutes of operation it must be switched off
for 30 minutes.
Note
During treatment, hold the atomiser straight (verti
-
cal), otherwise the atomisation does not work and
correct function cannot be guaranteed.
Important
Essential oils, cough medicines, solutions designed
for gargling, and drops for application to the skin or
for use in steam baths are wholly unsuitable for inha-
lation using a nebuliser. These substances are often
highly viscous and can impair the correct function of
the device and hence affect the effectiveness of its
application in the long term.
In the case of oversensitivity of the bronchial system,
medicines containing essential oils can sometimes
cause acute bronchiospasm (a sudden, cramp-like
tightening of the bronchi accompanied by breathless-
ness). Always ask your doctor or pharmacist for advice!
7. End of inhalation
If the spray is only output sporadically or if the noise
changes during inhalation, you can end the treatment.
Switch off the nebuliser after treatment using the on/
off switch [3] and disconnect it from the mains.
After use, replace the atomiser [9] in its holder [7].
8. Clean the device
For information about this, see “Cleaning and disinfec-
tion” on page 15.
7.Changing the filter
In normal operating conditions, the air filter must be
replaced after approx. 500 operating hours or one year.
Please check the air filter regularly (after 10-12 nebu-
lisation procedures).
If the filter is very contaminated or blocked, replace the
used filter. If the filter has become wet, it must also be
replaced with a new one.
Caution
Do not try to clean and re-use the used filter!
Only use original filters supplied by the manufacturer.
Otherwise, your nebuliser may become damaged or
effective therapy can no longer be guaranteed.
Do not repair or maintain the air filter while it is in use.
Never operate the device without a filter.
To replace the filter, proceed as follows:
Caution
First switch off the unit and unplug it.
Allow the unit to cool down.
1. Remove filter cap [5] upwards.
Note
If the filter remains in the unit when the cap is removed,
remove the filter from the unit using tweezers or similar.
2. Replace the filter cap [5] containing the new filter.
3. Check that the filter cap is firmly in place.
8. Cleaning and disinfection
Atomiser and accessories
Warning
Observe the following hygiene instructions in order to
avoid any health risks.
The atomiser
[9] and accessories are intended for
multiple use. Please note that cleaning requirements
differ according to the different application areas.
Notes:
The atomiser and accessories must not be me-
chanically cleaned with brushes or similar as this
can cause irreparable damage and the success of
the treatment can no longer be guaranteed.
For additional requirements regarding the necessary
hygienic preparations (hand washing, handling of
medicines or inhalation solutions) in high-risk groups
(e.g. cystic fibrosis patients), contact your doctor.
Ensure that all parts are properly dried following all
cleaning and disinfection. Residual moisture or water
droplets can result in an increased risk of bacterial
growth.
Preparation
Directly following each treatment, all parts of the
atomiser [9] and any accessories used must be
cleaned of medicine residues and contamination.
To do this, dismantle the atomiser [9] into its com-
ponent parts.
16
Remove the mouthpiece [13], mask
[14,15] or nosepiece [16] from the
atomiser.
Dismantle the atomiser by twisting
the upper section anti-clockwise
against the medicine container
[12].
Remove the nozzle attachment [10]
from the medicine container [12].
• Remove the valve [11] by pulling
it out of the atomiser [9].
The nebuliser is later reassembled in the reverse or-
der.
Cleaning
Important
Before you clean the unit, always switch it off, unplug
it and let it cool off.
The atomiser and the used accessories such as the
mouthpiece, mask, nozzle attachment, etc. must be
washed with hot but not boiling water after each use.
Carefully dry all components using a soft cloth. Once
all components are fully dry, reassemble the atomiser
and place the components in a dry, sealed container
or carry out disinfection.
When cleaning, ensure that all residues are removed.
Never use any substances that may be poisonous
when in contact with the skin or mucous membranes,
or when swallowed or inhaled.
Use a soft, dry cloth and non-abrasive cleaning prod
-
ucts to clean the device.
Do not use abrasive detergents and never immerse
the unit in water.
Important
Ensure that no water penetrates inside the unit!
Do not put the device or accessories in a dishwasher.
Do not touch the unit with wet hands while it is
plugged in; do not allow any water to be sprayed
onto the unit. The unit must be operated only when
it is completely dry.
Do not spray any liquids into the ventilation slots. Any
liquid that penetrates into the unit can damage the
electrical parts or other components of the nebuliser
and impair the function of the device.
Condensation, care of the hose
Depending on the environmental conditions, con-
densation may collect in the hose. To prevent against
bacterial growth and to ensure effective therapeutic
use, this moisture must always be removed. To remove
moisture from the hose, proceed as follows:
Remove the hose [8] from the atomiser [9].
Leave the hose plugged into the nebuliser [6].
Run the nebuliser until all the moisture has been dis-
placed by the flow of air.
In the event of significant contamination, replace the
hose.
Disinfection
Follow the steps listed below carefully in order to disin-
fect your atomiser and the accessories. It is advisable
to disinfect the individual components after the last
time they are used each day at the latest.
(For disinfection, you will simply require a small amount
of clear vinegar and distilled water).
First clean the atomiser and the accessories as de-
scribed under “Cleaning”.
Place the disassembled nebuliser, mouthpiece and
nosepiece in boiling water for five minutes.
For the remaining accessories,
use a vinegar solution
consisting of ¼ vinegar and ¾ distilled water. Make
sure that the volume is sufficient to fully submerge
the parts in the solution.
Leave the components in the vinegar solution for 30
minutes.
Rinse the parts with water and dry carefully with a
soft cloth.
Important
Do not boil or autoclave the masks and air hose.
Once all components are fully dry, reassemble the
atomiser and place the components in a dry, sealed
container.
Note
Ensure that all parts are thoroughly dried during, and
in particular after cleaning, otherwise there is an in-
creased risk of bacterial growth.
Sterilisation
Use the cold sterilisation solutions according to the
manufacturer's instructions.
Drying
Place the individual components on a dry, clean and
absorbent surface and allow to dry completely (for
at least 4 hours).
Material resistance
As with all plastic components, frequent use and
cleaning of the atomiser and the accessories can
lead to a certain amount of wear. Over time, this can
alter the aerosol properties and may eventually affect
the efficiency of therapy. We therefore recommend
that you replace the atomiser once a year.
10
11
12
17
When choosing a cleaning or disinfecting agent, note
the following: Only use mild cleaning or disinfect-
ant agents in the quantities recommended by the
manufacturer.
Storage
Do not store the nebuliser in a damp atmosphere
(e.g. in the bathroom) or transport it together with
damp objects.
Store and transport the nebuliser away from direct
sunlight.
The accessories can be safely stored in the acces-
sories compartment [4]. Store the device in a dry
place, if possible in its original packaging.
9. Disposal
In the interest of environmental protection, do not dis-
pose of the device in household waste.
Please dispose of the device in accordance with
EC Directive – WEEE (Waste Electrical and Elec-
tronic Equipment).
If you have any queries, please contact the ap
-
propriate local authorities.
10. Troubleshooting
Problem/Ques-
tion
Possible Cause/Remedy
The atomiser
produces
little or no
aerosol.
1. Too much or too little medicine
in the atomiser.
Minimum: 2 ml,
Maximum: 8 ml.
2. Check that the nozzles are not
blocked If necessary, clean
the nozzle (e.g. by rinsing).
Use the atomiser again.
CAUTION: Only poke imple
-
ments through the fine holes
from the underside of the
nozzle.
3. The atomiser is not held in an
upright position.
4. The medicine solution is
unsuitable for nebulising (e.g.
too thick).
The medicine solution should
be specified by the doctor.
Output is too
low.
Hose kinked, filter blocked, too
much inhalation solution.
Which
medicines are
suitable for
inhalation?
Consult your doctor.
Essentially all medicines that
are suitable and approved for
device-based inhalation can be
inhaled.
Problem/Ques-
tion
Possible Cause/Remedy
Some inhalation
solution
remains in the
atomiser.
This is normal and occurs for
technical reasons. Stop inhala
-
tion if you hear a notable differ-
ence in the noise of the atomiser.
What special
steps should be
taken for babies
and children?
1. In babies, the mask should
cover the mouth and nose to
guarantee effective inhalation.
2. In children, the mask should
also cover the mouth and
nose. Nebulisation next to a
sleeping person is not suitable
because insufficient medicine
reaches the lungs.
Note: Children should only use
the device with help and under
supervision of an adult. Never
leave a child alone with the
nebuliser.
Inhalation with
the mask takes
longer.
This is for technical reasons.
Less medicine is inhaled per
breath through the mask holes
than using the mouthpiece. The
aerosol is mixed with ambient air
through the holes in the mask.
Why do I need
to replace the
atomiser at
regular inter
-
vals?
There are two reasons for this:
1. To guarantee a therapeutically
effective particle spectrum,
the nozzle holes should not
exceed a certain diameter.
Due to the thermal and me
-
chanical stresses, the plastic
is subjected to a certain
amount of wear. The nozzle
attachment [10] is particularly
susceptible to this wear. This
can also cause changes to
the droplet composition of the
aerosol, which has a direct ef-
fect on the effectiveness of the
treatment.
2. You are also recommended
to replace the atomiser on
a regular basis for hygiene
reasons.
Does each per
-
son need their
own atomiser?
This is absolutely necessary for
hygiene reasons.
18
11. Technical specifications
Model IH 21
Type IH 21/1
Dimensions
(WxHxD) 300 x 180 x 100 mm
Weight 1.65 kg
Operating
pressure approx. 0.8 - 1.45 bar
Atomiser fill
volume
max. 8 ml
min. 2 ml
Medicine flow ca. 0.3 ml/min.
Sound pressure max. 52 dBA
(acc. to DIN EN 13544-1 section 26)
Mains
connection
230 V~; 50 Hz; 230 VA
UK: 240 V~; 50 Hz; 240 VA
Operating
conditions
Temperature: +10 °C to +40 °C
Relative humidity: 10% to 95%
Storage and
transport
conditions
Temperature: 0 °C to +60 °C
Relative humidity: 10% to 95%
Atmospheric pressure:
500 to 1060 hPa
Aerosol
Properties
1) Flow: 5.3 l/min
2) Aerosol delivery: 0.216 ml
3)
Aerosol delivery rate: 0.112 ml/min
4) Particle size (MMAD): 3.85 µm
Subject to technical modifications.
Particle size diagram
Measurements were performed using a sodium
fluoride solution with a "Next Generation Impac-
tor" (NGI).
This diagram may not be applicable for suspensions
or highly viscous medicines. More information can be
obtained from the relevant medicine manufacturer.
Spare parts
Designation Material REF
Nebulisation stopper PP
162.819
Yearpack (contains Mouth-
piece, Nosepiece, Adult mask,
Child mask, Atomiser, Com-
pressed air hose, Filter)
PP/ PVC 601.22
Note
If the unit is used outside of the specifications, proper
function is no longer guaranteed!
We reserve the right to make technical changes to im
-
prove and further develop the product.
This device and its accessories comply with European
standards EN60601-1 and EN60601-1-2, as well as
EN13544-1, and is subject to special safety measures
in terms of electromagnetic tolerance. Note that port
-
able and mobile RF communication equipment can
affect this unit. More details can be requested from
the stated Customer Service address or found at the
end of the instructions for use. The unit conforms to
the requirements of the European Directive for Medical
Products 93/42/EC, the MPG (German Medical units
Act).
ELECTROMAGNETIC COMPATIBILITY
The device complies with current specifications with
regard to electromagnetic compatibility and is suit-
able for use in all premises, including those des-
ignated for private residential purposes. The radio
frequency emissions of the device are extremely low
and in all probability do not cause any interference
with other devices in the proximity.
It is recommended that you do not place the device
on top of or close to other devices. Should you notice
any interference with other electrical devices, move
the unit or connect it to a different socket.
Radio equipment may affect the operation of this
device.
19
Sommaire
Eléments fournis
Voir la description de l’appareil et des accessoires
page 21.
Inhalateur
Nébuliseur
Flexible à air comprimé
Embout buccal
Masque pour adulte
Masque pour enfant
Embout nasal
Filtre de rechange
Notice d’utilisation
1. Apprendre à connaître
Cher cliente, cher client,
Nous vous remercions d’avoir choisi l’un de nos pro-
duits. Notre société est réputée pour l’excellence de
ses produits et les contrôles de qualité approfondis
auxquels ils sont soumis, dans les domaines suivants :
chaleur, contrôle du poids, diagnostic de pression arté-
rielle, mesure de température du corps et du pouls,
thérapies douces, massage et purification d’air.
Lisez attentivement cette notice, conservez- la pour un
usage ultérieur, mettez-la à la disposition des autres
utilisateurs et suivez les consignes qui y figurent.
Sincères salutations,
votre équipe Beurer
Domaine d’application
Cet inhalateur est un appareil servant à la nébulisation
de liquides et de médicaments liquides (aérosols) et
au traitement des voies respiratoires supérieures et
inférieures.
La nébulisation et l’inhalation d’un médicament prescrit
ou recommandé par le médecin permet de prévenir les
maladies des voies respiratoires, de limiter leurs effets
secondaires et d’accélérer la guérison. Consultez votre
médecin ou pharmacien pour en savoir plus sur les
possibilités d’utilisation.
L’appareil est conçu pour l’inhalation à domicile. L’in
-
halation de médicaments ne doit s’effectuer que sur
avis médical. Soyez calme et détendu pour procéder
à l’inhalation. Inspirez lentement et profondément afin
que le médicament parvienne jusqu’aux bronches les
plus fines et les plus lointaines. Expirez normalement.
Après préparation, l’appareil est approprié pour une
réutilisation. La préparation comprend le remplacement
de tous les accessoires, y compris du nébuliseur et
du filtre à air, ainsi qu’une désinfection de la surface
de l’appareil à l’aide d’un désinfectant d’usage dans
le commerce.
2. Symboles utilisés
Voici les symboles utilisés dans la notice d’utilisation :
Avertissement Ce symbole vous avertit des
risques de blessures ou des
dangers pour votre santé.
Attention Ce symbole vous avertit des
éventuels dommages au
niveau de l’appareil ou d’un
accessoire.
Remarque
Ce symbole indique des infor-
mations importantes.
Voici les symboles utilisés sur l’emballage et sur la
plaque signalétique de l’appareil et des accessoires :
Partie d’application, type BF
Lire la notice d’utilisation
Appareil de classe 2
F
abricant
I
Marche
O
Arrêt
SN
Numéro de série
30 ON /
30 OFF
après 30minutes d’utilisation, il doit être
arrêté pendant 30minutes
Protéger contre l’humidité
FRANÇAIS
1. Apprendre à connaître .......................................19
2. Symboles utilisés ............................................... 19
3. Consignes d’avertissement et de sécurité ........20
4. Description de l’appareil et des accessoires ..... 21
5. Mise en service ..................................................22
6. Utilisation ........................................................... 22
7. Changement du filtre .........................................24
8. Nettoyage et désinfection .................................24
9. Mise au rebut ..................................................... 25
10. Dépannage ........................................................26
11. Caractéristiques techniques ..............................26
20
3. Consignes d’avertissement et de
sécurité
Avertissement
Avant l’utilisation, assurez-vous qu’aucun dommage
apparent n’est visible sur l’appareil et les acces-
soires. En cas de doute, n’utilisez pas l’appareil et
adressez-vous à votre revendeur ou à votre service
aprèsvente.
En cas de panne de l'appareil, consultez le chapitre
«10. Solutions aux problèmes».
L’usage de l’appareil ne se substitue pas à une
consultation chez le médecin, ni à un traitement.
Par conséquent, en cas de douleur ou de maladie
de toute nature, consultez toujours d’abord votre
médecin.
En cas de doutes de quelque nature que ce soit
concernant votre santé, consultez votre médecin
traitant.
Respectez les mesures générales d’hygiène pour
l’utilisation du nébuliseur.
Conformez-vous aux indications du médecin pour ce
qui est du type de médicament à utiliser, du dosage,
de la fréquence d’administration et de la durée de
l’inhalation.
Utilisez uniquement les médicaments qui ont été
prescrits ou recommandés par votre médecin ou
pharmacien.
Attention
Pour le traitement, n'utilisez que les pièces recom
-
mandées par le médecin, correspondant à l'évolution
de la maladie.
Vérifiez sur la notice du médicament qu'il n'existe
pas de contre-indication à une utilisation avec les
systèmes habituels de thérapie par aérosols.
En cas de fonctionnement erratique de l’appareil, de
malaise ou de douleurs, interrompez immédiatement
le traitement.
Tenez l’appareil loin de vos yeux pendant l’utilisation
pour les protéger du nuage de médicament.
Ne faites pas fonctionner l’appareil en présence de
gaz inflammables.
Cet appareil n’est pas conçu pour être utilisé par
des enfants ou des personnes dont les facultés phy-
siques, sensorielles (par ex. insensibilité à la douleur)
ou psychiques sont limitées ou manquant d’expé-
rience et/ou des connaissances nécessaires. Elles
peuvent toutefois s’en servir à condition de le faire
sous la surveillance d’une personne responsable de
leur sécurité ou de suivre les directives de cette der
-
nière.
Avant chaque nettoyage et/ou chaque entretien,
l'appareil doit être éteint et débranché.
Ne laissez pas l’emballage à la portée des enfants
(risque d’étouffement).
Pour éviter tout risque d'empêtrement et d'étran-
glement, conservez les câbles et les conduites d'air
hors de portées des jeunes enfants.
N’utilisez pas de pièces supplémentaires ou d’acces-
soires non recommandés par le fabricant.
L’appareil doit uniquement être raccordé à la tension
secteur indiquée sur la plaque signalétique.
N’immergez pas l’appareil sous l’eau et ne l’utilisez
pas dans des locaux humides. Aucun liquide ne doit
pénétrer dans l’appareil.
Protégez l’appareil contre les chocs importants.
Ne touchez jamais le câble d’alimentation avec les
mains humides, vous risquez de recevoir une dé-
charge électrique.
Ne débranchez pas la fiche secteur de la prise de
courant en tirant sur le câble.
Ne pincez pas le câble, ne le pliez pas, ne le tendez
pas sur des objets à arêtes vives, ne le laissez pas
pendre et protégez- le de la chaleur.
Nous recommandons de dérouler entièrement le
câble d'alimentation pour éviter toute surchauffe
dangereuse.
Si le câble d’alimentation électrique de l’appareil
est endommagé, il doit être remplacé par le fabri-
cant, son service clients ou toute autre personne
qualifiée afin d’éviter tout danger.
Un risque de choc électrique existe si vous ouvrez
le corps de l’appareil. La déconnexion du réseau
d’alimentation n’est garantie que si la fiche secteur
est débranchée de la prise de courant.
Si l’appareil est tombé, a été soumis à une humidité
importante ou garde des séquelles de sa chute, il
ne doit plus être utilisé. En cas de doute, contactez
votre service après-vente ou votre revendeur.
L’inhalateur IH 21 ne peut être utilisé qu’avec
des nébuliseurs et accessoires adaptés. L’utili-
sation de nébuliseurs et d’accessoires d’une autre
marque peut nuire à l’efficacité du traitement et,
dans certains cas, endommager l’appareil.
Attention
Une coupure de courant, des perturbations ou
d’autres conditions défavorables peuvent entraîner
une indisponibilité de l’appareil. Il est par conséquent
recommandé de disposer d’un appareil de remplace-
ment ou d’un médicament (prescrit par le médecin).
Si des adaptateurs ou des rallonges sont néces-
saires, ils doivent satisfaire aux consignes de sécu-
rité qui s’appliquent. La tension d’alimentation maxi-
male et la puissance électrique maximale indiquée
sur l’adaptateur ne doivent pas être dépassées.
L’appareil et le câble d’alimentation ne doivent pas
être conservés à proximité de sources de chaleur.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Beurer IH 21 Instructions For Use Manual

Tip
Instructions For Use Manual

Diğer dillerde