Installation instructions
TR4000 | TR4000R – 6720876021 (2022/04)
14
CAUTION
Earthed water pipes may give the appearance of a connected
protective earth.
• During installation, an all-pole separator must be fitted
with a minimum contact gap of 3 mm, according to
chapter 4.
• Ensure that the inlet water pressure, maximum and
minimum, is according with the value specified by the
manufacturer ( chapter 4).
• The water inlet of this appliance shall not be connected to
inlet water obtained from any water heating system.
• The continuous-flow heater is suitable for connection to
DVGW-tested plastic pipes.
• After installation, electrically live parts must be touch
protected.
• The appliance should be disconnected from the electrical
mains supply when working on the water supply. After
service work is complete, proceed as during the first-time
appliance start-up.
• The electrical mains supply and the water supply must
be shut off before all work on the appliance.
• No changes may be made to the appliance.
• The warm water pipe may be hot. Please inform and
instruct children appropriately.
• If the power cord of this unit is damaged, it must be
replaced by the manufacturer, an authorised servicing
agent or a similarly qualified person so as to avoid danger.
• Do not use aggressive or abrasive cleaning detergents!
• Do not use a steam cleaner.
• The appliance is only to be descaled by a suitably qualified
specialist.
HSafety of electrical devices for domestic use and similar
purposes
The following requirements apply in accordance with EN
60335-1 in order to prevent hazards from occurring when
using electrical appliances:
“This appliance can be used by children of 3 years and older, as
well as by people with reduced physical, sensory or mental
capabilities or lacking in experience and knowledge, if they are
supervised and have been given instruction in the safe use of
the appliance and understand the resulting dangers. Children
shall not play with the appliance. Cleaning and user
maintenance must not be performed by children without
supervision.”
“If the power cable is damaged, it must be replaced by the
manufacturer, its customer service department or a similarly
qualified person, so that risks are avoided.”
Please read this installation and operating instruction
manual carefully, then act accordingly!
Store for future reference.
2 Installation instructions
Install the continuous-flow heater as described in the
illustrated section. Observe the instructions in the text.
2.1 Unpacking
• Inspect the new appliance for transport damage!
• Please dispose of the packaging, and if applicable,
the old appliance in an environmentally-friendly manner.
Scope of delivery
(Fig. 1)
1. Housing
2. Mounting (3 screws, 3 wall plugs)
3. Operation indicator
(only on TR4000 6 EB and TR4000 8 EB)
4. Installation bracket
5. Mounting bracket
6. Aerator
7. Documentation
2.2 Product description
The electronic continuous-flow heater is suitable for closed
(pressurised) connections. It heats the water as it passes
through the appliance.
The continuous-flow heater switches on and heats the water
when the warm water tap is opened. It switches off as soon
as the tap is closed.
The appliance may not be operated with pre-heated water,
as otherwise the overtemperature protection will trip.
This installation and operating instruction manual describes
various appliance types:
Over-sink appliances:
•TR4000 6 EB and TR4000 8 EB:
for fixed electrical connection
Undersink appliances:
•TR4000 4 ET and TR4000R 4 ET: with plug connection
•TR4000 5 ET, TR4000 6 ET and TR4000 8 ET:
for fixed electrical connection
Only for permanently installed appliances:
The device is compliant to IEC 61000-3-12.
Preparations for installation
(Fig. 2)