Control Panel for the Compact Type ATW Heat Pump
Thank you for choosing commercial air conditioners. Please read
this Owner’s Manual carefully before operation and retain it for
future reference.
ȈĮȢİȣȤĮȡȚıIJȠȪȝİʌȠȣİʌȚȜȑȟĮIJİİʌĮȖȖİȜȝĮIJȚțȐ țȜȚȝĮIJȚıIJȚțȐ.
ȆĮȡĮțĮȜȫįȚĮȕȐıIJİ ĮȣIJȩ IJȠ ǼȖȤİȚȡȓįȚȠ țĮIJȩȤȠȣʌȡȠıİțIJȚțȐ
ʌȡȚȞ Įʌȩ IJȘ ȜİȚIJȠȣȡȖȓĮ țĮȚ įȚĮIJȘȡȒıIJİ IJȠ ȖȚĮ ȝİȜȜȠȞIJȚțȒ
ĮȞĮijȠȡȐ.
To Users
Thank you for selecting this product. Please read this instruction manual carefully before installing and using the
product, so as to master and correctly use the product. In order to guide you to correctly install and use our
product DQGDFKLHYHH[SHFWHGRSHUDWLQJHႇHFWZHKHUHE\LQVWUXFWDVEHORZ
(1) This instruction manual is a universal manual, some functions are only applicable to particular product. All
the illustrations and information in the instruction manual are only for reference.
(2) All the illustrations and information in the instruction manual are only for reference. In order to make the
product better, we will continuously conduct improvement and innovation without further notice.
(3) For personal injury or property loss and damage caused by improper operation such as improper
installation and debugging, unnecessary maintenance, violation of related national laws and rules and
industrial standard, and violation of this instruction manual, etc., we will bear no liability
(4) The final right to interpret this instruction manual belongs to TOYOTOMI CO, LTD
Contents
Safety Notices (Please be sure to abide) ....................................................................4
1. General ........................................................................................................................5
1.1 Home Page .......................................................................................................................5
1.2 Menu Page ........................................................................................................................6
1.3 Backlight ...........................................................................................................................7
2. Operation Instructions ..............................................................................................7
2.1 ON/OFF ............................................................................................................................7
2.2 Function Setting ................................................................................................................8
2.3 User Parameter Setting ..................................................................................................18
2.4 Commissioning Parameter Setting .................................................................................19
2.5 Viewing ...........................................................................................................................29
2.6 General Setting ...............................................................................................................34
3. Intelligent Control ...................................................................................................35
3.1 Installing Ewpe Smart APP .............................................................................................37
3.2 Setting Main Functions ...................................................................................................40
3.3 Setting Other Functions .................................................................................................41
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 4
Safety Notices (Please be sure to abide)
Do not install the control where it is damp or exposed to direct sunlight.
Once the air conditioning unit is installed where possibly subject to electromagnetic interference, shielded
twisted pairs should be used as signal lines and other communication lines.
Be sure communication lines are wired to the correct ports, or normal communication would fail.
Do not beat, toss or frequently assemble and disassemble this control.
Do not operate the control with wet hands!
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB5
1. General
(This picture is just for reference)
This display panel uses the capacitor touch screen for input operation. The valid touching area indicates the
EODFNUHFWDQJOHZKHQWKHGLVSOD\SDQHOOLJKWVRႇ
This control panel is of high sensitivity and will response to unexpected click by the foreign matters on the
display panel. Therefore, please keep it clean during operation.
This is a generous-purpose controller, whose control functions might not be completely the same as those of the
actually purchased. As the control program will update, the actual always prevails.
1.1 Home Page
Icon Description Icon Description
Space heating Outdoor temperature
Space cooling Leaving water temperature of the main unit, leaving water
temperature of the auxiliary electric heater, remote room temperature
Water heating Error
Menu Card out/Failed disinfection
Switchover
between cooling
and heating
ON/OFF
Child lock
[Notes]
Ɣ7KH212))LFRQZLOOWXUQWRJUHHQZKHQWKHFRQWUROLVWXUQHGRQ
Ɣ:KHQWKHFRQWUROPRGHLV³Room temperature”, the temperature displayed at the upper right corner indicates
WKHUHPRWHURRPWHPSHUDWXUHZKHQWKHFRQWUROPRGHLV³leaving water temperature”, it indicates the leaving
water temperature of the auxiliary electric heater under the water heating mode, or the leaving water temperature
of the main unit under the cooling/heating mode or combined modes.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 6
Ɣ 8QGHUWKHFRPELQHGPRGHVWKHWHPSHUDWXUHVHWSRLQWLVIRUVSDFHKHDWLQJRUFRROLQJ
2QO\XQGHUWKHZDWHU heating mode, it is for water heating.
Ɣ ,WZLOOJREDFNDXWRPDWLFDOO\WRWKHKRPHSDJHZKHQWKHUHLVQRDQ\RSHUDWLRQLQWHQPLQXWHV
1.2 Menu Page
Menu Page
Above the menu, the corresponding icon will be displayed based on the mode and status of the controller.
No Item Description
1 Current mode Current mode
2 Data Current data
3 Time Current time
4 Function setting Go to the user setting page.
5 Parameter setting Go to the parameter setting page.
6 Parameter viewing Go to the parameter viewing page.
7 Commissioning parameters Go to the commissioning parameter setting page.
8 ON/OFF
,WLVXVHGWRWXUQRQRURႇWKHXQLW³OFF´LQGLFDWHVWKHXQLWKDVWXUQHGRႇDQG³ON
indicates the unit has turned on. When there is failure-level error, this button will
turn to OFFRQFHWKHXQLWLVDXWRPDWLFDOO\WXUQHGRႇ
9 General setting Go to the general parameter setting page.
10 Homepage Back to the home page.
Icon Description Icon Description
Heating Floor commissioning
Cooling Floor commissioning error
Hot water Card out
Heating + Hot water Defrosting
Hot water + Heating Holiday
Cooling + Hot water WiFi
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB7
Hot water + Cooling Back
Quiet Menu page
Sanitation Save
Emergency Error
[Notes]
Ɣ7KH³Cooling” mode is unavailable to the heating only unit.
Ɣ7KH³Hot water” mode is unavailable to the heating only unit.
Ɣ7KH³Heating + Hot water´³Hot water” takes the priority) is unavailable to the mini chiller.
Ɣ7KH³Hot water + Heating´³Heating” takes the priority) is unavailable to the mini chiller.
Ɣ7KH³Cooling + Hot water´³Hot water” takes the priority) is unavailable to the mini chiller.
Ɣ7KH³Hot water + Cooling´³Cooling” takes the priority) is unavailable to the mini chiller.
Ɣ7KH³Sanitation” function is unavailable to the mini chiller.
Error Icon
1.3 Backlight
$PRQJWKHJHQHUDOVHWWLQJSDJHZKHQ³Back light´LVVHWWR³Energy save´WKHGLVSOD\SDQHOZLOOOLJKWRႇZKHQ
there is no operation in 5 minutes. However, it will light on again by touching any valid area.
:KHQ³Back light´LVVHWWR³Lighted”, the display panel will be kept lighting on.
,WLVVXJJHVWHGWRVHWLWWR³Energy save” so as to extend its service life.
2. Operation Instructions
2.1 ON/OFF
[Operation Instructions]
$WWKHPHQXSDJHE\WRXFKLQJ212))WKHXQLWZLOOEHWXUQHGRQRႇ
[Notes]
Ɣ,WLVGHIDXOWHGWREH2))XSRQ¿UVWSRZHURQ
Ɣ212))RSHUDWLRQZLOOEHPHPRUL]HGE\VHWWLQJ³2Q2ႇ0HPRU\´WREH³On´DWWKH³GENERAL.” setting page.
7KDWLVLQFDVHRISRZHUIDLOXUHWKHXQLWZLOOUHVXPHUXQQLQJXSRQSRZHUUHFRYHU\2QFH³2QRႇ0HPRU\” is set to
EH³2ႇ´LQFDVHRISRZHUIDLOXUHWKHXQLWZLOONHHS³2ႇ” upon power recovery.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 8
ON Page
2.2 Function Setting
[Operation Instructions]
$WWKHPHQXSDJHE\WRXFKLQJ³FUNCTION”, it will go to the function setting page as shown in the figure
below.
FUNCTION Setting Page
2.At the function setting page, by touching the page turning key, it will access to the last or next page. When
VHWWLQJLV¿QLVKHGE\WRXFKLQJWKHPHQXSDJHLFRQLWZLOOGLUHFWO\EDFNWRWKHPHQXSDJHE\WRXFKLQJWKHEDFN
icon, it will back to the upper menu.
3.At the function setting page, by pressing the desired function, it will access to the corresponding setting page
of this option.
$WWKHIXQFWLRQVHWWLQJSDJHRIVRPHIXQFWLRQRSWLRQE\WRXFKLQJ³OK”, this setting will be saved; by touching
WKH³CANCEL” key, this setting will be canceled.
[Notes]
Ɣ$WWKHIXQFWLRQVHWWLQJSDJHZLWKVHWWLQJRIDQ\IXQFWLRQFKDQJHGLIWKHIXQFWLRQLVVHWWREHPHPRUL]HGXSRQ
SRZHUIDLOXUHWKLVVHWWLQJZLOOEHVDYHGDXWRPDWLFDOO\DQGPHPRUL]HGXSRQQH[WSRZHURQ
Ɣ:KHQWKHUHLVVXEPHQXIRUWKHVHOHFWHGIXQFWLRQRSWLRQE\SUHVVLQJLWWKHFRQWUROZLOOJRGLUHFWO\WKHVHWWLQJ
page of the submenu.
Ɣ³1$´ZLOOEHGLVSOD\HGIRUXQDYDLODEOHIXQFWLRQVRIWKHKHDWLQJRQO\XQLWVDQGPLQLFKLOOHUV:KHQVHWWLQJWKHVH
functions, the controller will tell setting of this parameter is unallowed.
Function Setting
No Item Range Default Remarks
1 Mode
Cool
Heat
1. When the water tank is unavailable, then only
³Cool´DQG³Heat” are available.
2. For the heating only unit, only "HeatPRGH³+RW
ZDWHU´DQG³+HDWKRWZDWHU´DUHDYDLODEOH
,WLVGHIDXOWHGWREH³Heat” for the heat pumps and
KHDWLQJRQO\XQLWVDQG³Cool” for mini chillers.
Heat
Hot water
Cool + Hot water
Heat + Hot water
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB9
No Item Range Default Remarks
2 Fast hot water 2Q2ႇ 2ႇ 1. When the water tank is unavailable, it will be
reserved.
3 Cool + hot water Cool/Hot water Hot water
1. When the water tank is available, it will be
GHIDXOWHGWREH³Hot water”; when unavailable, it will
be reserved.
4 Heat + hot water Heat/Hot water Hot water
1. When the water tank is available, it will be
GHIDXOWHGWREH³Hot water”; when unavailable it will
be reserved.
5 Quiet mode 2Q2ႇ 2ႇ /
6 Quiet timer 2Q2ႇ 2ႇ /
7 Weather depend 2Q2ႇ 2ႇ /
8 Weekly timer 2Q2ႇ 2ႇ /
9 Holiday release 2Q2ႇ 2ႇ
10 Disinfection 2Q2ႇ 2ႇ
When the water tank is unavailable, it will be reserved
The disinfection date ranges from Monday to Sunday.
Saturday is defaulted.
7KHGLVLQIHFWLRQWLPHUDQJHVIURP
aLVGHIDXOWHG
11 Clock timer 2Q2ႇ 2ႇ /
12 Temp. timer 2Q2ႇ 2ႇ /
13 Emergen. mode 2Q2ႇ 2ႇ /
14 Holiday mode 2Q2ႇ 2ႇ /
15 Preset mode 2Q2ႇ 2ႇ /
16 Error reset / / Some error can be cleared only when it has been
reset manually.
17 WiFi reset It is used to reset the WiFi.
18 Reset / / It is used to reset all user parameter setting.
19 Child Lock 2Q2ႇ 2ႇ /
2.2.1 Mode
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHZLWKWKHXQLWWXUQHGRႇE\WRXFKLQJ³Mode”, it will go to the mode setting page,
ZKHUHGHVLUHGPRGHFDQEHVHOHFWHG7KHQE\WRXFKLQJ³OK” this setting will be saved and the display panel will
back to the function setting page.
[Notes]
Ɣ7KHGHIDXOWPRGHLV³Heat´XSRQ¿UVWSRZHURQ
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 10
Ɣ0RGHVHWWLQJLVDOORZHGRQO\ZKHQWKHXQLWLVWXUQHGRႇRWKHUZLVHDGLDORJER[ZLOOSRSXSVD\LQJ³3OHDVHWXUQ
RႇWKHV\VWHP¿UVW´
Ɣ:KHQWKHZDWHUWDQNLVXQDYDLODEOHRQO\³Heat´DQG³Cool” mode are allowed.
Ɣ:KHQWKHZDWHUWDQNLVDYDLODEOH³Cool´³Heat´³Hot water´³Cool+ Hot water´DQG³Heat+ Hot water” are
allowed.
Ɣ)RUWKHKHDWSXPSWKH³Cool´PRGHLVDOORZHGIRUWKHKHDWLQJRQO\XQLW³Cool+ Hot water´DQG³Cool” are
unallowable.
Ɣ7KLVVHWWLQJFDQEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.2 Fast Hot Water
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHZLWKWKHXQLWWXUQHGRႇE\WRXFKLQJ³Fast hot water”, the display panel will go to the
FRUUHVSRQGLQJVHWWLQJSDJHZKHUHGHVLUHGRSWLRQFDQEHVHOHFWHG7KHQE\SUHVVLQJ³OK” this setting will be saved
and the display panel will back to the function setting page.
[Notes]
Ɣ7KLVIXQFWLRQFDQEHVHWWR³On” only when the water tank is available. When the water tank is unavailable, this
function will be reserved.
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
Ɣ7KLVIXQFWLRQLVXQDYDLODEOHWRPLQLFKLOOHUV
2.2.3 Cool + Hot water
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHZLWKWKHXQLWWXUQHGRႇE\WRXFKLQJ³Cool + hot water”, the display panel will go to
WKHFRUUHVSRQGLQJVHWWLQJSDJHZKHUHGHVLUHGRSWLRQFDQEHVHOHFWHG7KHQE\SUHVVLQJ³OK” this setting will be
saved and the display panel will back to the function setting page.
[Notes]
Ɣ:KHQWKHZDWHUWDQNLVXQDYDLODEOHLWZLOOEHUHVHUYHGZKHQLWLVXQDYDLODEOHWKHGHIDXOWSULRULW\ZLOOEHJLYHQ
WR³How water.
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
Ɣ7KLVIXQFWLRQLVXQDYDLODEOHWRPLQLFKLOOHUV
2.2.4 Heat + Hot water
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHZLWKWKHXQLWWXUQHGRႇE\WRXFKLQJ³Heat + hot water”, the display panel will go to
WKHFRUUHVSRQGLQJVHWWLQJSDJHZKHUHGHVLUHGRSWLRQFDQEHVHOHFWHG7KHQE\SUHVVLQJ³OK” this setting will be
saved and the display panel will back to the function setting page.
[Notes]
Ɣ:KHQWKHZDWHUWDQNLVXQDYDLODEOHLWZLOOEHUHVHUYHGZKHQLWLVXQDYDLODEOHWKHGHIDXOWSULRULW\ZLOOEHJLYHQ
WR³Hot water”.
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
Ɣ7KLVIXQFWLRQLVXQDYDLODEOHWRWKHKHDWLQJRQO\XQLWDQGWKHPLQLFKLOOHU
2.2.5 Quiet Mode
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHZLWKWKHXQLWWXUQHGRႇE\WRXFKLQJ³Quiet mode”, there will be a choice box, where
³Quiet mode´FDQEHVHWWR³On´³2ႇ´RU³Timer”.
:KHQLWLVVHWWR³Timer´LWLVDOVRUHTXLUHGWRVHWWKH³Start timer´DQG³End timer”. Unless otherwise stated,
otherwise time setting is all the same.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB11
Timer for Quite Mode
This setting will be saved by touching the corner at the upper right corner.
[Notes]
Ɣ,WFDQEHVHWXQGHUERWK21DQG2))VWDWXVHVEXWZLOOZRUNRQO\ZKHQWKHPDLQXQLWLVWXUQHGRQ
Ɣ:KHQLWLVVHWWR³On´LWZLOODXWRPDWLFDOO\EDFNWR³2ႇ´ZKHQWKHPDLQXQLWLVWXUQHGRႇZKLOHLWLVVHWWR³Timer”,
WKLVVHWWLQJZLOOUHPDLQZKHQWKHPDLQXQLWLVWXUQHGRႇDQGFDQRQO\EHFDQFHOHGPDQXDOO\
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.6 Weather Depend
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHE\WRXFKLQJ³Weather depend”, there will be a choice box, where it is able to set it
WR³On´RU³2ႇ”, and also it is able to set the weather-dependent temperature.
Page of the Weather Depend
[Notes]
Ɣ:KHQ³Weather depend” has been activated; it cannot be deactivated by ON/OFF operation but done
manually.
Ɣ,WLVDYDLODEOHWR¿QGWKHZHDWKHUGHSHQGHQWWDUJHWWHPSHUDWXUHDWWKDWSDUDPHWHUYLHZLQJSDJHV
Ɣ:KHQWKLVIXQFWLRQKDVEHHQDFWLYDWHGLWLVVWLOODOORZHGWRVHWWKHURRPWHPSHUDWXUHKRZHYHUWKLVVHWWLQJ
EHFRPHVYDOLGRQO\ZKHQ³Weather depend” has been deactivated.
Ɣ7KLVIXQFWLRQFDQEHVHWWR³On´QRPDWWHUWKHXQLWLVWXUQHGRQRURႇEXWZRUNVRQO\ZKHQWKHXQLWLVWXUQHG
on.
Ɣ,WZRUNVXQGHUWKH³Cool´RU³Heat´PRGH8QGHUWKH³Cool +Hot water´RU³Heat +Hot water” modes, it works
RQO\ZKHQWKHFXUUHQWPRGHLV³Cool´RU³Heat´8QGHUWKH³Hot water” mode, it doesn’t work.
Ɣ7HPSHUDWXUHVHWWLQJUHODWLYHWRWKHFRROLQJPRGHLVXQDOORZHGWRWKHKHDWLQJRQO\XQLW
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
Ɣ:KHQWKHVHWSRLQWRI³Upper WT-Heat´³Upper WT-Cool´LVORZHUWKDQWKDWRIWKH³Lower WT-Heat´³Lower
WT-Cool´RU³Lower WT-Heat´³Lower WT-Cool´LVKLJKHUWKDQ³Upper WT-Heat´³Upper WT-Cool”, a window
ZLOOSRSXSVD\LQJ³Enter wrong!”, and then resetting is required.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 12
2.2.7 Weekly Timer
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHE\WRXFKLQJ³Weekly timer”, it will go to the setting page as shown below.
$WWKH³Weekly timer´VHWWLQJSDJHDVVKRZQLQWKH¿JXUHEHORZWKHZHHNO\WLPHUFDQEHVHWWR³On´RU³2ႇ”.
$WWKH³Weekly timer´VHWWLQJSDJHE\WRXFKLQJWKHGHVLUHGGD\0RQGD\a6XQGD\LWZLOODFFHVVWRWKHVHWWLQJ
page of this option.
$WWKHZHHNGD\VHWWLQJSDJHLWLVDEOHWRVHWWKHWLPHUWR³Valid´RU³Invalid”. Also, it is able to set three timing
SHULRGVHDFKRIZKLFKFDQEHVHWWR³Valid´RU³Invalid”.
7KHQE\WRXFKLQJWKH³Save” icon, this setting will be saved.
[Notes]
Ɣ7KUHHSHULRGVFDQEHVHWIRUHDFKGD\7KHVWDUWWLPHVKRXOGEHHDUOLHUWKDQWKHHQGWLPHIRUHDFKSHULRG
otherwise this setting will be invalid. In the same way, the latter should be earlier than the former.
Ɣ:KHQWKHZHHNO\WLPHUKDVEHHQDFWLYDWHGWKHGLVSOD\SDQHOZLOODFWEDVHGRQWKHFXUUHQWPRGHDQG
temperature setting.
Ɣ7LPHUVHWWLQJIRUWKHZHHNGD\
³Valid´LWLQGLFDWHVWKLVVHWWLQJZRUNVRQO\ZKHQ³Weekly timer´KDVEHHQDFWLYDWHGXQDႇHFWHGE\WKHKROLGD\
mode.
³Invalid´LQGLFDWHVWKLVVHWWLQJGRHVQRWZRUNHYHQWKRXJKWKH³Weekly timer” has been activated.
Ɣ:KHQERWK³Weekly timer´DQG³Holiday release´KDYHEHHQDFWLYDWHGVHWWLQJRI³Weekly timer” is invalid.
2QO\ZKHQ³Holiday release´KDVEHHQGHDFWLYDWHGVHWWLQJRI³Weekly timer” works.
Ɣ7KHSULRULW\VHTXHQFHIRUWLPHUVHWWLQJIURPKLJKWRORZLV³Temperature timer´³Clock timer´³Preset mode”
DQG³Weekly timer”. Setting with lower priority sequence is allowed but does not work when setting with higher
priority has been activated. However, it will work when the setting with higher priority has been deactivated.
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.8 Holiday Release
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHE\WRXFKLQJ³+ROLGD\UHOHDVH´LWZLOOJRWRWKHFRUUHVSRQGLQJVHWWLQJSDJHZKHUHLW
FDQEHVHWWR³On´RU³2ႇ”.
[Notes]
Ɣ:KHQWKLVIXQFWLRQKDVEHHQDFWLYDWHGDWWKHµWeekly timer” setting page, some week day can be set to
³Holiday release´,QWKLVFDVHWKHVHWWLQJRIWKH³Weekly timer” at this day is invalid unless it has been manually
VHWWR³Valid”.
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.9 Disinfection
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHDFFHVVWR³Disinfection” setting page.
$WWKH³Disinfection” setting page, it can select the disinfection clock, disinfection temperature and disinfection
week and the corresponding setting page will pop up at the right side.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB13
7KHQWKLVVHWWLQJZLOOEHVDYHGE\WRXFKLQJWKH³Save” icon.
[Notes]
Ɣ7KLVIXQFWLRQLVXQDYDLODEOHWRPLQLFKLOOHUV
Ɣ7KLVVHWWLQJFDQEHDFWLYDWHGRQO\ZKHQ³Water tank´LVVHWWR³With´:KHQ³:DWHUWDQN´LVVHWWR³Without”,
this function will be deactivated.
Ɣ7KLVVHWWLQJFDQEHGRQHQRPDWWHULIWKHXQLWLVWXUQHGRQRURႇ
Ɣ:KHQ³Emergen.mode´³Holiday mode´³Floor debug´³Manual defrost´RU³Refri. recovery” has been
DFWLYDWHGWKLVIXQFWLRQFDQQRWEHDFWLYDWHGDWWKHVDPHWLPH:KHQ³Disinfection´KDVEHHQDFWLYDWHG³Emergen.
mode´³Holiday mode´³Floor debug´³Manual defrost´RU³Refri. recovery” setting will fail and a window will
SRSXSVD\LQJ³Please disable the disinfect mode!
Ɣ³Disinfection´FDQEHDFWLYDWHGQRPDWWHULIWKHXQLWLVWXUQHGRQRURႇ7KLVPRGHZLOOWDNHSULRULW\RYHUWKH³Hot
water” mode.
Ɣ:KHQGLVLQIHFWLRQRSHUDWLRQIDLOVWKHGLVSOD\SDQHOZLOOWHOO³Disinfection fail!”. Then, by pressing OK it will be
cleared.
Ɣ:KHQ³Disinfection” has been activated, if communication error with the indoor unit or malfunction of the
water tank heater occurs, it will automatically quit.
Ɣ,WZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.10 Clock Timer
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHDFFHVVWRWKH³Clock timer” setting page.
$WWKH³Clock timeU´VHWWLQJSDJHLWFDQEHVHWWR³On´RU³2ႇ”.
7KHRSWLRQ³Mode´LVXVHGWRWLPHWKHGHVLUHGPRGH³WOT-Heat´DQG³T-water tank” is used to set the
FRUUHVSRQGLQJZDWHUWHPSHUDWXUH³Period´LVXVHGWRIRUWLPHVHWWLQJ$IWHUWKDWE\WRXFKLQJWKH³Save” icon, all
settings will be saved.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 14
[Notes]
Ɣ:KHQ³Clock timer´KDVEHHQVHWDQG³Hot water´PRGHLVLQYROYHGLQWKLVFDVHLI³Water tank” is changed
WR³Without´³Hot water´ZLOOEHDXWRPDWLFDOO\VZLWFKHGWR³Heat´DQG³Cool/Heat + Hot water” will be switched to
³Cool/Heat”.
Ɣ:KHQ³Weekly timer´DQG³Clock timer” have been set at the same time, the priority will be given to the
former.
Ɣ:KHQWKHZDWHUWDQNLVDYDLODEOH³Heat´³Cool´³Hot´³Heat + Hot water´DQG³Cool + Hot water” are
DOORZHGKRZHYHUZKHQWKHZDWHUWDQNLVXQDYDLODEOHRQO\³Heat´DQG³Cool” are allowed.
Ɣ:KHQWKHHQGWLPHLVHDUOLHUWKDQWKHVWDUWWLPHWKLVVHWWLQJLVLQYDOLG
Ɣ:DWHUWDQNWHPSHUDWXUHFDQEHVHWRQO\ZKHQ³Hot water” is involved in the operation mode.
Ɣ7KHVHWWLQJRI³Clock timer” only works once. If this setting is needed again, it should be set again.
Ɣ,WZLOOEHGHDFWLYDWHGZKHQWKHXQLWLVWXUQHGRQPDQXDOO\
Ɣ:KHQ³Weather depend´KDVEHHQDFWLYDWHGDQGWKHPRGHIRU³Clock timer´LVVHWWR³Hot water´³Weather
depend” will be deactivated when the setting mode has been switched.
Ɣ7KLVIXQFWLRQZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.11 Temp. Timer
$WWKHIXQFWLRQVHWWLQJSDJHDFFHVVWRWKH³Temp.timer” setting page.
$WWKH³Temp.timer´VHWWLQJSDJHLWFDQEHVHWWR³On´RU³2ႇ”.
6HOHFW³Period 1´³Period 2´DQGDZLQGRZZLOOSRSXSZKHUHWLPHSHULRGFDQEHVHW7KHQVHOHFW³WT-Heat1/
WT-Cool 1/2” and also a window will pop up where temperature can be set.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB15
[Notes]
Ɣ:KHQ³Weekly timer´³Preset mode´³Clock timer´³Temp. timer” have been set at the same time, then the
latter takes the priority.
Ɣ7KLVVHWWLQJLVYDOLGRQO\ZKHQWKHXQLWLVWXUQHGRQ
Ɣ8QGHUWKH³Cool´RU³Cool+Hot water´PRGHWKHVHWWLQJWDUJHWVDW³WT-CooO´ZKLOHXQGHUWKH³Heat” or
³Heat+Hot water´PRGHWKHVHWWLQJWDUJHWVDW³:7+HDW´
Ɣ:KHQVWDUWWLPHRISHULRGLVWKHVDPHDVWKDWRISHULRGWKHQWKHIRUPHUWDNHVSUHYDOHQFH
Ɣ³Temp.timer” is judged based on timer.
Ɣ'XULQJWKLVVHWWLQJZKHQWHPSHUDWXUHLVVHWPDQXDOO\WKHQWKLVVHWWLQJZLOOWDNHSUHYDOHQFH
Ɣ8QGHUWKH³Hot water” mode, this function will be reserved.
Ɣ7KLVIXQFWLRQZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.12 Emergen. Mode
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHVHWWKHPRGHWR³Heat´RU³Hot water”.
$WWKHIXQFWLRQVHWWLQJSDJHVHOHFW³(PHUJHQPRGH´DQGVHWLWWR³On´RU³2ႇ”.
:KHQ³Emergen.mode” has activated, the corresponding icon will appear at the upper side of the menu page.
:KHQWKHPRGHLVQRWVHWWR³Heat´RU³Hot water´WKHGLVSOD\SDQHOZLOOWHOO³Wrong running mode!
[Notes]
Ɣ7KHHPHUJHQF\PRGHLVDOORZHGRQFRQGLWLRQVWKDWWKHUHLVVRPHHUURURUSURWHFWLRQDQGWKHFRPSUHVVRUKDV
stopped at least for three minutes. If the error or protection has not been recovered, the unit can access to the
HPHUJHQF\PRGHWKURXJKWKHZLUHGFRQWUROOHUZKHQWKHXQLWLVRႇ
Ɣ8QGHUWKHHPHUJHQF\PRGH³Hot water´RU³Heat” cannot be performed at the same time.
Ɣ:KHQWKHUXQQLQJPRGHLVVHWWR³Heat´LI³Other thermal´RU³Optional E-Heater´LVVHWWR³Without”, the unit
ZLOOIDLOWRDFFHVVWRWKH³Emergen. mode”.
Ɣ:KHQWKHXQLWSHUIRUPV³+HDW´XQGHU³(PHUJHQPRGH´DQGWKHFRQWUROOHUGHWHFWV³HP-Water Switch”,
³Auxi. heater 1´³Auxi. heater 1´DQG³Temp-AHLW”, this mode will quit at once. In the same way, when errors
PHQWLRQHGDERYHRFFXU³Emergen. mode” cannot be activated.
Ɣ:KHQWKHXQLWSHUIRUPV³Hot water´XQGHU³Emergen. mode´DQGWKHFRQWUROOHUGHWHFWV³Auxi.-WTH”, this
PRGHZLOOTXLWDWRQFH,QWKHVDPHZD\ZKHQHUURUVPHQWLRQHGDERYHRFFXU³Emergen. mode” cannot be
activated.
Ɣ:KHQWKLVIXQFWLRQKDVEHHQDFWLYDWHG³Weekly timer´³Preset mode´³Clock timer´DQG³Temp timer” will
EHGHDFWLYDWHG%HVLGH³2Q2ႇ´³Mode´³Quiet mode´³Weekly timer´³Preset mode´³Clock timer´DQG³Temp
timer” operation are unavailable.
Ɣ8QGHU³Emergen. mode”, the thermostat does not work.
Ɣ7KLVIXQFWLRQFDQEHDFWLYDWHGRQO\ZKHQWKHXQLWLVWXUQHGRII,IGRVLQJVRZLWKWKHXQLWNHHSLQJ³On”, a
ZLQGRZZLOOSRSXSVD\LQJ³3OHDVHWXUQRႇWKHV\VWHP¿UVW”.
Ɣ³Floor debug´³Disinfection´DQG³Holiday mode” cannot be activated at the same with this function. When
GRLQJVRDZLQGRZZLOOSRSXSVD\LQJ³Please disable the emergen. mode!”.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 16
Ɣ8SRQSRZHUIDLOXUH³Emergen. mode´ZLOOEDFNWR³2ႇ”.
2.2.13 Holiday Mode
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHVHOHFW³Holiday mode´DQGVHWLWWR³On´RU³2ႇ.
[Notes]
Ɣ7KLVIXQFWLRQFDQEHDFWLYDWHGRQO\ZKHQWKHXQLWKDVEHHQWXUQHGRႇRWKHUZLVHDSURPSWGLDORJER[ZLOOSRS
XSVD\LQJ³3OHDVHWXUQRႇWKHV\VWHPIULVW.
Ɣ:KHQ³Holiday mode´KDVEHHQDFWLYDWHGWKHRSHUDWLRQPRGHZLOODXWRPDWLFDOO\VZLWFKWR³Heat”. Mode
VHWWLQJDQG³2Q2ႇ" operation through the controller will be unavailable.
Ɣ:KHQ³Holiday mode´KDVEHHQDFWLYDWHGWKHFRQWUROOHUZLOODXWRPDWLFDOO\GHDFWLYDWHWKH³Weekly timer” and
³Preset mode´DQG³Clock timer´DQG³Temp.timer”.
Ɣ8QGHUWKH³Holiday mode”, when the unit is under the control of room temperature, the set point (room
temperature for heating) should be set to 10°C; when it is under the control of leaving water temperature, the set
point (leaving water temperature for heating) should be 30°C.
Ɣ:KHQWKLVIXQFWLRQKDVEHHQDFWLYDWHG³Floor debug´³Emergen.mode´³Disinfection´³Manual defrost”,
³Preset mode´³Weekly timer´³Clock timer´DQG³Temp.timer” cannot be activated at the same time,
PHDQZKLOHDZLQGRZZLOOSRSXSVD\LQJ³Please disable the holiday mode!”.
Ɣ7KLVIXQFWLRQZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
2.2.14 Preset Mode
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHVHOHFW³Preset mode” and go to the corresponding setting page.
$WWKHWLPHSHULRGVHWWLQJSDJHHDFKWLPHSHULRGFDQEHVHWWR³Valid´RU³Invalid”.
7KHRSWLRQ³Mode´LVXVHGWRSUHVHWWKHPRGH³WOT-Heat” is used to set the leaving cold/hot water
WHPSHUDWXUH³Start timer´³End timer´LVXVHGWRIRUWLPHVHWWLQJ$IWHUWKDWE\WRXFKLQJWKH³Save” icon, all
settings will be saved.
[Notes]
Ɣ:KHQ³Preset mode´KDVEHHQVHWWR³Hot water´DQG³Water tank´LVWRVHWWR³Without´WKHSUHVHW³Hot
water´PRGHZLOOEHDXWRPDWLFDOO\VZLWFKHGWR³Heat”.
Ɣ:KHQ³Weekly timer´DQG³Preset mode” both have been set, priority will be given to the latter.
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB17
Ɣ:KHQWKHZDWHUWDQNLVDYDLODEOHWKHSUHVHWPRGHFDQEH³Heat´³Cool´RU³Hot water”; however, when the
ZDWHUWDQNLVXQDYDLODEOHWKHSUHVHWPRGHFDQRQO\EH³Heat´RU³Cool”.
Ɣ³Start timer´VKRXOGEHHDUOLHUWKDQ³End timer´RWKHUZLVHDGLDORJZLOOSRSXSVD\LQJ³time setting wrong”.
Ɣ7KHVHWWLQJIRU³Preset mode” will works until it has been canceled manually.
Ɣ:KHQ³Start timer” is reached, the unit will perform the preset mode. In this case, mode and temperature
VHWWLQJDUHVWLOODOORZHGEXWZLOOQRWEHVDYHGWRWKHSUHVHWPRGH:KHQ³End timer” is reached, the unit will perform
OFF operation.
Ɣ7KLVIXQFWLRQZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
Ɣ:KHQ³Weather depend´KDVEHHQDFWLYDWHGDQGWKHPRGHIRU³Preset mode´LVVHWWR³Hot water´³Weather
depend” will be deactivated when the setting mode has been switched.
2.2.15 Error Reset
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHE\WRXFKLQJ³Error reset´DFKRLFHER[ZLOOSRSXSZKHUHE\WRXFKLQJ³OK” the
HUURUZLOOEHUHVHWDQGE\WRXFKLQJ³Cancel” the error will not be reset.
[Notes]
Ɣ,WFDQEHSHUIRUPHGRQO\ZKHQWKHXQLWLVWXUQHGRႇ
2.2.16 WiFi Reset
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHE\WRXFKLQJ³WiFi´DFKRLFHER[ZLOOSRSXSZKHUHE\WRXFKLQJ³OK” , the WiFi
VHWWLQJZLOOEHUHVHWDQGE\WRXFKLQJ³Cancel” the choice box will quit and WiFi will not be reset.
2.2.17 Reset
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHE\WRXFKLQJ³Reset´DFKRLFHER[ZLOOSRSXSZKHUHE\WRXFKLQJ³OK” all user
SDUDPHWHUVHWWLQJVZLOOEHUHVHWDQGE\WRXFKLQJ³Cancel” it will back to the function setting page.
[Notes]
Ɣ7KLVIXQFWLRQLVDOORZHGRQO\ZKHQWKHXQLWKDVWXUQHGRႇ
Ɣ7KLVIXQFWLRQLVYDOLGIRU³Temp. timer´³Clock timer´³Preset mode´³Weekly timer´DQG³Weather
depend”.
2.2.18 Child Lock
[Operation Instructions]
$WWKHIXQFWLRQVHWWLQJSDJHE\WRXFKLQJ³Child Lock´LWFDQEHVHWWR³On´RU³2ႇ”.
:KHQLWLVVHWWR³On”, the controller will go back to the home page and a lock icon will be diplayed, as
VKRZQLQWKH¿JXUHEHORZ
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 18
In this case, the controller is locked and any touch operation does not work. By touching for six seconds,
the controller will be unlocked and touch operation will work. However, the setting of "Child Lock" will remain to be
"On", and if there is no any operation in 30 seconds, the controller will be locked again.
2QO\ZKHQLWLVVHWWR³2ႇ”, this function will be really disenabled.
2.3 User Parameter Setting
[Operation Instructions]
$WWKHPHQXSDJHE\WRXFKLQJ³PARAMETER”, it will back to the parameter setting page, as shown in the
¿JXUHEHORZ
Parameter Setting Page
2.At the menu setting page, by touching the page turning keys, it is able to switch to the page where the desired
parameter is.
$IWHUWKDWWKLVVHWWLQJZLOOEHVDYHGE\WRXFKLQJ³OK” and then the unit will run based on this setting. While this
VHWWLQJZLOOJLYHXSE\WRXFKLQJ³Cancel”.
[Notes]
)RUSDUDPHWHUVZLWKGLႇHUHQWGHIDXOWVXQGHUGLႇHUHQWFRQGLWLRQVZKHQFRQGLWLRQVFKDQJHVWKHGHIDXOWYDOXH
also will change as the corresponding condition changes.
$OOSDUDPHWHUVZLOOEHPHPRUL]HGXSRQSRZHUIDLOXUH
Parameter Setting
No Full Name Displayed
Name
Range Range Default Remarks
(°C)(°F)
1
Leaving water
temperature for
cooling(T1)
WOT-Cool
a& a) 18 /64°F Unavailable to heating
only units
a& a) 18 /64°F
Applicable to the
second generation
Monobloc series units
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB19
No Full Name Displayed
Name
Range Range Default Remarks
(°C)(°F)
2
Leaving water
temperature for
heating (T2)
WOT-Heat
a& a) 45 /113°F High-temp series units
a& a) 45°C/113°F Normal-temp series
units
a& a) 45°C/113°F
Applicable to the
second generation
Monobloc series units
3Room temperature
for cooling (T3) RT-Cool a& a) 24°C/75°F Unavailable to heating
only units
4Room temperature
for heating (T4) RT-Heat a& a) 20°C/68°F /
5Water tank
temperature(T5) T-water tank a& a) 50°C/122°F Unavailable to mini
chillers
6
Leaving water
temperature
GLႇHUHQFHIRUFRROLQJ
ǻW
ǻ7&RRO a& a) 5°C/41°F Unavailable to mini
chillers
7
Leaving water
temperature
GLႇHUHQFHIRUFRROLQJ
ǻW
ǻ7+HDW a& a) 10°C/50°F /
8
Leaving water
temperature
GLႇHUHQFHIRUZDWHU
KHDWLQJǻW
ǻ7KRWZDWHU a& a) 5°C/41°F Unavailable to mini
chillers
9
Room temperature
FRQWUROGLႇHUHQFH
ǻW
ǻ75RRP
temp a& a) 2°C/36°F /
2.4 Commissioning Parameter Setting
[Operation Instructions]
$WWKHPHQXSDJHE\WRXFKLQJ³Commission” and then entering the correct password (000048) in the pop-up
window, the commissioning parameter page will be accessed, where the left side is for the function setting and the
ULJKWVLGHLVIRUWKHSDUDPHWHUVHWWLQJDVVKRZQLQWKH¿JXUHEHORZ
[Notes]
Ɣ$WWKHFRPPLVVLRQLQJSDUDPHWHUVHWWLQJSDJHZKHQWKHVWDWHRIDQ\IXQFWLRQFKDQJHVWKHV\VWHPZLOO
automatically save this change and this change will remain upon power failure.
Ɣ'RQRWPRGLI\DQ\FRPPLVVLRQLQJSDUDPHWHUH[FHSWWKHDSSURYHGTXDOL¿HGVHUYLFHPHQDVLWZRXOGJLYHELUWK
WRDGYHUVHHႇHFWVWRWKHXQLW
Operation Instructions for the Compact Type ATW Heat Pump hydria+
GB 20
Commissioning Function Setting
No. Item Range Default Description
1 Ctrl. state T-water out/T-room T-water out :KHQ³Remote sensor´LVVHWWR³With”, it can
EHVHWWR³T-room”.
22-Way
valve
&RRO:D\YDOYH2Q2ႇ 2ႇ
It will decide the status of the 2-way valve under
WKH³Cool´DQG³Cool + Hot water” modes.
8QGHU³&RRO´RU³&RRO+RWZDWHU´PRGH
the status of the 2-way valve depends on this
setting. This setting is unavailable to heating
only units.
+HDW:D\YDOYH2Q2ႇ On It will decide the status of the 2-way valve under
WKH³Heat´DQG³Heat + Hot water” modes
5Solar
setting With/Without Without
When the water tank is unavailable, this setting
will be reserved.
:KHQLWLVVHWWR³With”, the solar kitting will work
on its own.
:KHQLWLVVHWWR³Without”, hot water by the
solar kitting is unavailable.
6 Water tank With/Without Without Unavailable to mini chillers.
7Thermostat
Without/Air/Air+ hot water/
Air+ hot water2 Without
7KLVVHWWLQJFDQQRWEHLQWHUFKDQJHGDPRQJ³Air
³Air+ hot water” and "Air+ hot water2" directly
EXWYLD³Without” this option.
2Q2ႇ 2ႇ This setting is available to mini chillers.
8Other
thermal With/Without Without /
9Optional
E-Heater 2ႇ 2ႇ /
10 Remote
sensor With/Without Without :KHQLWVHWWR³:LWKRXW´DQGWKH³&WUOVWDWH´ZLOO
EHGHIDXOWHGWREH³7ZDWHURXW´
11 Air removal 2Q2ႇ 2ႇ /
12 Floor debug 2Q2ႇ 2ႇ /
13 Manual
defrost 2Q2ႇ 2ႇ /
14 Force mode 2ႇ)RUFHFRRO)RUFHKHDW 2ႇ ³Force-cool is unavailable to heating only units.
15 Tank heater Logic 1/Logic 2 Logic 1
1. This setting is allowed when the water tank is
available and the unit is OFF.
2. Unavailable to mini chillers.
16 Gate-Ctrl. 2Q2ႇ 2ႇ /
17 C/P limit 2໤&XUUHQWOLPLW3RZHU
limit 2໤
&XUUHQWOLPLWLWUDQJHVIURPWR$DQGWKH
default is 16A.
3RZHUOLPLWLWUDQJHVIURPWRN:DQGWKH
default is 3.0kW.
18 Address [1-125] [127-253] 1 /
19 Refri.
recovery 2Q2ႇ 2ႇ /
20 Gate-Ctrl
memory 2Q2ႇ 2ႇ /
21 3-Way
valve1 Without/DHW/AIR Without /
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Toyotomi THMU414-1R32 El kitabı

Tip
El kitabı