Franke Consumer Products FPL 607 I XS 645H Kullanım kılavuzu

Kategori
Ocak davlumbazları
Tip
Kullanım kılavuzu
FPL 607 I
FPL 907 I
FPL 457 I XS 645H
FPL 607 I XS 645H
FPL 907 I XS 645H
IT
FR
DE
TR
HR
PL
GB
EN
2
2
IT
3
3
FR
4
4
DE
5
5
TR
6
6
HR
7
7
PL
8
8
!
! !
"
EN
9
9
650 mm min.
EN
1
0
10
*
**
*
**
EN
1
1
11
23
22
12h
11
15
24
1
12f
2
7.1
7.1b
7.1a
21
12g
12w
14
26
12c
13
9
25
EN
1
2
12
Use a plumb line to mark the centre of the hob on the ceiling/support shelf.
Place the drilling template 21 provided on the ceiling/support shelf, making sure that the
template is in the correct position by lining up the axes of the template with those of the hob.
Mark the centres of the holes in the template.
Drill the holes at the points marked:
• For concrete ceilings, drill for plugs appropriate to the screw size.
For hollow brick ceilings with wall thickness of 20 mm: drill ø 10 mm(immediately insert
the Dowels 11 supplied).
• For wooden beam ceilings, drill according to the wood screws used.
• For wooden shelf, drill ø 7 mm.
• For the power supply cable feed, drill ø 10 mm.
For the air outlet (Ducted Version), drill according to the diameter of the external air ex-
haust duct connection.
Insert two screws of the following type, crossing them and leaving 4-5 mm from the ceiling:
• For concrete ceilings, use the appropriate plugs for the screw size (not provided).
for Cavity ceiling with inner space, with wall thickness of approx. 20 mm, Screws 12h,
supplied.
• For wooden beam ceilings, use 4 wood screws (not provided).
• For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided.
EN
1
3
13
If you wish to adjust the height of the frame, proceed
as follows:
Unfasten the metric screws joining the two columns,
located at the sides of the frame.
Adjust the frame to the height re
quired, then
replace all the screws removed as above.
Fix the Fixing Part of the Upper Chimney 26 to the
hanging kit using the 2 screws 12w (M3 x 8).
Lift up the frame, fit the frame slots onto the screws
up to the slot end positions.
Tighten the two screws and fasten the other two
screws provided; before locking the screws com-
pletely, it is possible to adjust the frame by turning it,
making sure that the screws do not come out of their
housing in the adjustment slot.
It is now possible to place and tighten the 4 safety
screws, Proceed as follows:
drill the ceiling with a 10 mm ø bit taking as refer-
ence the holes of the side parts of the upper chim-
ney fixing part.
insert the 4 dowels (provided).
insert the washers (provided) to the screws and
tighten the screws
The Frame must be securely fastened so as to support
both the weight of the Hood and the stress caused by
occasional axial pressure against the fitted Appli-
ance. After fixing, make sure that the base is stable
even when the Frame is subjected to lateral stress.
If the Ceiling is not strong enough in the area where
the hood is to be fixed, the Installer must strengthen
the area using suitable plates and counterplates an-
chored to resistant structures.
2
2
1
1
12w
26
EN
1
4
14
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
Fix the pipe using the pipe clamps 25 provided.
Remove any activated charcoal filters.
9
ø 150
ø 120
25
25
Insert the reducer flange 9 on the air outlet of the extractor.
Attach the adhesive Novastik gasket 13 to the air outlet con-
nection 15 and fix this to the upper frame using the 2 knobs 24.
Fix the air outlet connection extension piece 14 to the air outlet
connection 15.
Connect the hood air outlet to the flange in the lower part of
the junction using a rigid or flexible ø 120 tube (by installer’s
choice).
14
15
24
15
14
15
9
EN
1
5
15
Insert the upper duct and fix it on the top of the upper duct
connection using the 12c screws (2.9 x 9.5) supplied with the
appliance.
Recirculation version
It is necessary to make sure that the air outlet connection 15 is
placed correctly so that the air outlet grid in it corresponds to
that of the chimney.
If the grids of the two parts are not corresponding to each
other, it will be necessary to remove the chimney and to adjust
the position of the air outlet connection 15, and at last to as-
sembly the parts again by following the earlier indications.
Before fixing the hood body to the frame:
Open the suction panel by turning the specific knob.
Disconnect the panel from the hood canopy by sliding the fix-
ing pin lever.
Remove the grease filters from the hood body.
Remove any activated charcoal filters.
From below, use the 4 screws 12f (M6 x 10) provided to fix the
hood body to the frame.
12c
12f
Connect the Hood to the mains power supply, inserting a two-
pole cut-out switch with contact aperture of at least 3 mm
along the line.
Pull the Comfort Panel to open it, ensure that the supply cable
connector is properly inserted into the Suction device socket
Join the connectors.
Install the odour filter and the charcoal filter in case the hood is
to be used in recycling version.
Install the grease filter again, and successively the suction
panel.
EN
1
6
16
A B C D E F G H
Key Function Display
A
Switches the extractor motor on and off at the
latest selected speed
Indicates the selected speed.
B
Decreases the suction speed.
C
Increases the suction speed.
D
the intensive speed from any previously se-
lected speed. The intensive speed can be acti-
vated even when the motor is OFF. This speed
has been timed at 10 minutes. After that time
the system activates automatically the latest
cooking conditions when vapours and smells
are of the utmost emission.
HI appears. The spot down on the right side
flashes once a second.
E
By pressing this key it is possible to set up the
motor to a suction speed at 100 m
3
/h lasting 10
minutes every hour. After this the motor
switches off automatically.
When the filter saturation is going on it is pos-
sible to reset the alarm by pressing this key for
about 3 seconds. The indication is visible only
when the motor is off.
Indicates the 24-function. The spot down on
the right side flashes and the motor is on.
Once the process is finished the previous indi-
cation disappears:
FF Indicates that the metal grease filters
saturation alarm has been triggered, and
the filters need to be washed. The alarm
is triggered after 100 working hours.
EF Indicates that the charcoal filter satura-
tion alarm has been triggered, and the fil-
ter has to be replaced; the metal grease
filters must also be washed. The charcoal
filter is triggered after 200 working hours.
F
By pressing this key it is possible to set the
delayed shutdown of the appliance to 30 min-
utes. This function is suitable for a complete
elimination of the residual smells. It can be
activated at any position, and it is deactivated
by pressing the key again or by switching off
the motor.
Indicates alternately the selected speed of the
hood and the time left before the hood shut-
down. The spot down on the right side flashes.
G
Turns light on and off .
H
Turns light on and off at reduced intensity.
EN
1
7
17
The appliance can be controlled using a remote control powered
by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-
AAA type.
Do not place the remote control near to heat sources.
Used batteries must be disposed of in the proper manner.
Pull the Comfort Panel to open it.
Disconnect the panel from the hood canopy by sliding the fix-
ing pin lever.
The comfort panel must never be washed in a dishwasher.
Clean the outside using a damp cloth and neutral liquid deter-
gent.
Clean the inside as well using a damp cloth and neutral deter-
gent; do not use wet cloths or sponges, or jets of water; do not
use abrasive substances.
When the above operation has been completed, hook the panel
back to the hood canopy and close it by turning the knob in the
opposite direction.
EN
1
8
18
Filters can be washed in the dish machine. They need to
be washed when FF-sign appears on the display or in
any case every 2 months, or even more frequently in
case of particularly intensive use of the hood.
Alarm reset
Switch off the hood and the lights. If the 24h-
function has been activated this has to be deactivated.
Press the E-key till the display is unlit.
Cleaning the filters
Pull the comfort panels to open them.
Remove the filters one by one pushing them towards
the back side of the hood unit and simultaneously
pulling downwards.
Any kind of bending of the filters has to be avoided
when washing them. Before fitting them again into
the hood make sure that they are completely dry.
(The colour of the filter surface may change through-
out the time but this has no influence to the filter ef-
ficiency).
When fitting the filters into the hood pay attention
that they are mounted in correct position the handle
facing outwards.
Close the comfort panel.
EN
1
9
19
This filter cannot be washed or regenerated. It must be replaced when the EF appears on the
display or at least once every 4 months.
Activation of the alarm signal
In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
Switch off the hood and the lights.
Disconnect the hood from the mains supply.
When restoring the connection press and hold B-key.
When releasing the key two rotating rectangles appear on the display.
Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly:
2 flashes with EF - charcoal filter saturation alarm ACTIVATED
1 flash with EF - charcoal filter saturation alarm DEACTIVATED.
Reset of the alarm signal
Switch off the hood and the lighting. If the 24h-function has
been activated this has to be deactivated.
Press the E-key until the display is unlit.
Replacing of the filter
Open the comfort panels pulling them downwards.
Remove the metal grease filters.
Remove the saturated charcoal filter by releasing the fixing
hooks
Fit the new filter and fasten it in its correct position.
Put the metal grease filters in their seats.
Close the comfort panels.
20 W halogen light.
Remove the snap-on lamp cover by levering it from under the
metal ring, supporting it with one hand.
Remove the halogen lamp from the lamp holder by pulling
gently.
Replace the lamp with a new one of the same type, making
sure that you insert the two pins properly into the housings on
the lamp holder.
Replace the snap-on lamp cover.
IT
2
0
20
650 mm min.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Franke Consumer Products FPL 607 I XS 645H Kullanım kılavuzu

Kategori
Ocak davlumbazları
Tip
Kullanım kılavuzu